The words you are searching are inside this book. To get more targeted content, please make full-text search by clicking here.
Discover the best professional documents and content resources in AnyFlip Document Base.
Search
Published by anna.morrow, 2022-01-04 03:47:19

Quantum Rules Document

Quantum - Sizes - Rev D

We know washrooms.

Quantum Cubicle
Rules Document

Quantum Cubicle

Contents

Cubicle Standard Sizes, Limits & Rules 2 General Cubicle Rules 8

Cubicle Elements & Typical Configurations 3 Advanced Cubicle Rules – non-standard height 9

Standard Door Rules 4 Advanced Cubicle Rules – overpanels 10

Standard Partition Rules 5 Cubicle Components 11

Standard Pilaster Rules 6 Cubicle Accessories 12

Standard Pedestal Rules 7

Alderflat Drive, T 01782 277200 Page 1
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Cubicle Standard Sizes, Limits & Rules

FINISHED MATERIAL TYPE AND SIZES

SUPPLIER MATERIAL HEIGHT mm WIDTH mm THICKNESS mm
Pfleiderer 19
Pfleiderer MFC 2770 2070 19
Pfleiderer HPL 2770 2040 12.3
SGL 2770 1900

Material Floor Ceiling Cubicle Height O/A Cubicle
MFC 19mm Clearance Clearance From Floor Depth (mm) D
Required (mm) Level (mm) C Including Pilaster
(mm) A
B
Std 100
Min 60 Std 2100 Max Min
2097 142

HPL 19mm Std 100 Min 60 Std 2100 Max Min
2067 142

SGL 12.3mm Std 100 Min 60 Std 2100 Max Min
1921 121

Alderflat Drive, T 01782 277200 Page 2
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Cubicle Elements & Typical Configurations

Alderflat Drive, T 01782 277200 Page 3
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Standard Door Rules

DIAGRAM *1 *2, *3 & *4 *1 *4
MATERIAL INDICATOR BOLT HEIGHT From INDICATOR BOLT POSITION From
DOOR HEIGHT DOOR WIDTH TO OPENING
OPTIONS (mm) (mm) FFL (mm) door edge (mm)

OPEN IN HPL / MFC Std 2000 Std + 60 Std 1000 -82
OPEN OUT & SGL
Std 1000 -82
NOTES: HPL / MFC Std 1940mm Std + 35
& SGL

All HPL/MFC Doors over 750mm wide require 3 hinges

All SGL Doors have 3 hinges
Max door opening width 1200mm

Min door opening width 400mm ( requires Customer sign off as below 550mm std adult opening)

Alderflat Drive, T 01782 277200 Page 4
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle STANDARD PARTITION HEIGHT actual panel size (mm) STANDARD PARTITION WIDTH
Std 2000 (A) actual panel size (mm)
Standard Partition Rules
MAX MIN
MATERIAL
Max 2040 (B) Min 115 (C)
HPL
MFC Std 2000 (A) Max 2070 (B) Min 115 (C)
SGL
Std 2000 (A) Max 1900 (B) Min 100 (C)
NOTES
Pedestal to be positioned –100mm from front of cubicle (*1)
Pedestal required for partitions over 200mm wide (D)
Floor to Ceiling Post required for cubicles over MAX depth in a single piece
2no. partitions required fixed to central post with U channels (*2)
Floor to Ceiling Post to be positioned -300mm from front of cubicle for freestanding cubicles (*3)

Alderflat Drive, T 01782 277200 Page 5
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Standard Pilaster Rules

MINIMUM /STANDARD PILASTER DIMENSIONS (MM)

DIAGRAM *1 *2 *3 *4 *5 *6 *7
MATERIAL PILASTER HEIGHT
HPL / MFC WALL END HANGING WALL END CLAPPING OPEN END HANGING OPEN END CLAPPING INTER HANGING INTER CLAPPING
Std 2000
SGL STD MIN STD MIN STD MIN STD MIN STD MIN STD MIN
HPL / MFC
115 115 115 115 115 115 115 115 170 170 170 170
SGL V-dim (85) V-dim (85) V-dim (85)) V-dim (85)

OPEN IN Std 2000 115 100 115 100 115 100 115 100 170 170 170 170
OPEN OUT V-dim (85)) V-dim (85) V-dim (85)) V-dim (85)

Std 2000 115 115 115 115 115 115 115 115 170 170 170 170
V-dim (85)) V-dim (85) V-dim (85)) V-dim (85)

Std 2000 115 100 115 100 115 100 115 100 170 170 170 170
V-dim (85)) V-dim (85) V-dim (85)) V-dim (85)

Alderflat Drive, T 01782 277200 Page 6
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Standard Pedestal Rules

PILASTER DIMENSIONS

DIAGRAM *1 *2 *3 *4 *5 *6 *7 *8
MATERIAL PARTITION WALL END OPEN END
HANGING WALL END OPEN END CLAPPING INTER HANGING INTER CLAPPING OFFSET INTER
ALL ≥ 200 CLAPPING HANGING
x1 pedestal ≥ 140 ≥ 140 ≥ 260 ≥ 260 ≥ 210
PEDESTAL REQUIRED ≥ 140 ≥ 140 x1 pedestal x2 pedestals x2 pedestals x1 pedestal
(SEE DIAGRAMS) x1 pedestal x1 pedestal x1 pedestal (one each side) (one each side) (offset V-Dim 135)
-75
Remove pedestal from Remove pedestal from Pedestal remains on
partition
partition partition

PEDESTAL POSITION FROM EDGE ALL -100 -75 -75 -75 -65 -65 -75
OF PILASTER / PARTITION
Pedestal Height Tolerance = +10mm Max ( 2no. 5mm packers)
NOTES Inline pilaster (wall end or open end) 1000mm wide and above requires an additional pedestal
Inline pilaster (wall end or open end) 1200mm wide and above requires a floor to ceiling post
Floor to ceiling post positioned -250mm from pilaster edge (door opening side)
An open end pilaster must have a pedestal fitted if one cannot be fitted to the partition

Alderflat Drive, T 01782 277200 Page 7
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

General Cubicle Rules

• The DOC M Building Regulations clearly states - Paragraph 5.14 - WC compartments within separate sex washrooms will satisfy Requirement M1 or M3 If a: if the swing of any Inward opening doors to standard
WC compartments is such that a 450mm diameter manoeuvring space is maintained between the swing of the door, the WC pan and the side wall of the compartment. If this space is not available please, either
confirm that the customer is happy for us to continue or advise of any layout changes (i.e. doors open out or cubicle depth change

• Check WC pan projection - door width to be taken into account as comment above - if door swing is too close to the pan pilaster or partition sizes should be adjusted
• Disabled cubicle width 1500mm clear from wall to inside face of partition
• Disabled cubicle depth 2200mm clear from wall to inside face of pilaster
• Ambulant cubicle width min 800mm clear
• Ambulant cubicle should have 750mm activity space from WC pan to rear face of pilaster
• Enlarged cubicle width min1200mm clear
• Doors should be outward opening for Ambulant and Disabled WC’s.

Alderflat Drive, T 01782 277200 Page 8
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Advanced Cubicle Rules

MAXIMUM / MINIMUM DIMENSIONS

DOOR HEIGHT INDICATOR BOLT HEIGHT MATERIAL PILASTER HEIGHT PARTITION HEIGHT (mm) FLOOR O/ALL CUBICLE HEIGHT
(mm) FROM FFL (mm) (mm) CLEARANCE FROM FLOOR LEVEL (mm)

MATERIAL (mm)

MAX MIN MAX MIN MAX MIN MAX MIN STD MAX MIN

OPEN IN HPL / MFC 2770 1800 1200 500 ALL 2770 1800 2770 1800 100 2870 1900
OPEN OUT SGL 2770 1740 1200 500

HPL / MFC
SGL

Quantum non-standard height will not require special drilling patterns but will require a non-standard surcharge of 10%.

Alderflat Drive, T 01782 277200 Page 9
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Advanced Cubicle Rules

QUANTUM DOOR WITH OVERPANEL

MATERIAL STD DOOR HEIGHT (mm) LIFT OFF DOOR HEIGHT DOOR WIDTH TO OVERPANEL HEIGHT OVERPANEL WIDTH TO DOOR
(mm) OPENING (mm) (mm) OPENING (mm)

OPEN IN HPL / MFC Max 2540 Max 2510 Std + 60 Max 970 Std + 100
SGL Min 1770 Min 1740 Inline +70 Min 200 (50 each side)

Max 2540 Max 2510 Std + 60 Max 970 Std + 100
Min 1770 Min 1740 Inline +70 Min 200 (50 each side)

HPL / MFC Max 2540 Max 2510 Std + 60 Max 970 Std + 100
Min 1770 Min 1740 Inline +70 Min 200 (50 each side)
OPEN OUT
NOTES: SGL Max 2540 Max 2510 Std + 60 Max 970 Std + 100
Min 1770 Min 1740 Inline +70 Min 200 (50 each side)

Overpanel only available on std height cubicle and above
All Doors over 750mm wide require 3 hinges.

All SGL Doors have 3 hinges

Door width (inward & outward) = pilaster opening plus 60mm (35mm hanging & 25mm clapping)
+ 10mm for in-line

Max door opening width 1200mm

Min door opening width 400mm

* Quantum with overpanels will require special drilling details for Production and an overpanel fixing kit. Non-standard surcharge of 10% must be applied.

Alderflat Drive, T 01782 277200 Page 10
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle Material/Finish Code Notes Type Material/Finish Code Notes
1 per door 1 Per WE Pils
Cubicle Components Metal – Zinc 19mm U-Channel for 13mm Metal – Aluminium U Channel 2m: 2 Per Partition
Light Grey MFC/HPL: SGL Satin Anodised 0630018C2
Type 0333007T
Screw pack
Indicator Bolt 13mm SGL: 0046002N
0333007SG

Indicator Bolt Plastic – ABS 0332006 1 per door U-Channel for 19mm Metal – Aluminium U Channel 2m: 1 Per WE Pils
Light Grey MFC/HPL Satin Anodised 0630021C2 2 Per Partition

Screw pack:
0046003N

Pedestal Metal – Zinc 19mm 1 per inline pilaster Headrail for 13mm Metal – Aluminium Headrail 3m: To suit overall
Light Grey MFC/HPL: 2 if >1000 to 1199 SGL Satin Anodised 0331037N cubicle length
0333005T
Screw pack: 1 per headrail
13mm SGL: 0046014N
0333005SG 1 per return end
End cap: 0130004

Pedestal Plastic – ABS 0332030 1 per inline pilaster Headrail for 19mm Metal – Aluminium Headrail 3m: To suit overall
Light Grey 2 if >1000 to 1199 MFC/HPL Satin Anodised 0331036N cubicle length

Screw pack: 1 per headrail
0046015N
1 per return end
End cap: 0130003

Hinge for 13mm SGL Metal – Zinc Single hinge: 3 per door Z Keep for 19mm Metal – Aluminium Z Keep LH 2m: 1 per outward door
Light Grey 0330022N MFC/HPL (with Light Grey 0630114C2L 1 per outward door

fixings) Z Keep RH 2m:
0630114C2R
Z Keep for 13mm
SGL (with fixings) Fittings: 0046010N

Hinge for 19mm Metal – Zinc Single hinge: 2 Per Door Metal – Aluminium Z Keep LH 2m:
MFC/HPL Light Grey 0330012N 3 if >750 Light Grey 0630113C2L
2 per Child Door
Z Keep RH 2m:
0630113C2R

Fittings: 0046011N

Outward Opening Metal – Aluminium Single LH hinge: 2 Per Door Door Buffer Rubber 0300005 2 per door
Hinge Satin Anodised 0267100 3 if >750 Black
2 per Child Door
Single RH hinge:
0267101

Alderflat Drive, T 01782 277200 Page 11
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX

Quantum Cubicle

Cubicle Accessories

Type Material/Finish Code Standard? Notes Type Material/Finish Code Standard? Notes

Coat Hook ABS Light Grey 0300139 ✓ Standard for Coat Hook Brushed 19mm MFC/HPL: ✘
Award ABS 65mm Stainless Steel CH65T
Fittings
Coat Hook 13mm SGL:
Standard for 90mm CH65SG
Award Alu
Coat Hook Brushed 19mm MFC/HPL: ✓ Fittings Brushed 19mm MFC/HPL: ✘
30mm Stainless Steel CH30T Stainless Steel CH90T
Standard for
13mm SGL: Award ABS 13mm SGL:
CH30SG Fittings CH90SG

Toilet Roll ABS Light Grey 0300303 ✓ Toilet Roll Brushed 0302509 ✘
Holder Holder Stainless Steel

Lockable ABS Light Grey 0300403 Standard for Double Brushed 0302510 ✘
Toilet Roll Toilet Roll Stainless Steel
✓ Award ABS
Holder Fittings Holder

Lockable Standard for Jumbo Roll Brushed
✓Toilet Roll Satin finish zinc 0380074N Holder Stainless Steel ✘
Award Alu 0302500

Holder Fittings

Pull Handle Satin Anodised 225mm: 0182227 ✓ *Rose set is Pull Handle Brushed 225mm: 0182218 ✘ *Rose set is
Pair Aluminium 400mm: 0182226 optional extra, Pair Stainless Steel 400mm: 0182232 ✘ optional extra,
✘ allow 2 rose allow 2 rose
sets per handle sets per handle
Pull Handle Satin Anodised 225mm: 0182222 ✘ pair Pull Handle Brushed 225mm: 0182221 ✘ pair
Single Aluminium 400mm: 0182225 ✘ Single Stainless Steel 400mm: 0182216 ✘
*Must be *Must be
supplied with supplied with
rose set or bolt rose set or bolt
through disc set through disc set

Pull Handle Satin Anodised 0182231 ✘ Pull Handle Brushed 0182230 ✘
Rose Set Aluminium Rose Set Stainless Steel

Pull Handle Aluminium 0182229 ✘ Pull Handle Brushed 0182228 ✘
Bolt Through Bolt Through Stainless Steel

Disc Set Disc Set

Alderflat Drive, T 01782 277200 Page 12
E [email protected]
Newstead Industrial Estate www.venesta.co.uk
Trentham, Stoke-on-Trent

ST4 8HX


Click to View FlipBook Version