GA_Fibroblast_Pen_rev01_EN (1)

GA_Fibroblast_Pen_rev01_EN (1)

Instruction Manual

Purebeau Fibroblast Pen
Art. No.: 10.trs DS2
10.elite 3.5

Document: GA_Fibroblast_Pen_rev01

Purebeau Fibroblast Instruction Manual

Contents

Please note............................................................................. 2
Disclaimer ............................................................................. 2
Operating panel features ....................................................... 3
Information and part names .................................................. 4
Technical information ........................................................... 5
Operation............................................................................... 5
Safety instructions - Contraindications ................................. 6
Use ........................................................................................ 7
Cleaning and Maintenance.................................................... 8
Function testing Repairs Complaints .................................. 8
Hygiene instructions ............................................................. 9
Delivery contents .................................................................. 9
Guarantee policy ................................................................. 10

1 ga_fibroblast_pen_rev01_en

Purebeau Fibroblast Instruction Manual

Please note

This instruction manual outlines the intended uses of
the "PUREBEAU Fibroblast" device, and serves to
reduce any risks associated with possible
malfunction or damage to the device. Any person
wishing to handle, use, clean, maintain or otherwise
control this device must carefully read and follow this
instruction manual.

Disclaimer

This device must only be operated by authorised
medical professionals, cosmeticians, or other trained
personnel. Training by Purebeau New Cosmetics
GmbH is mandatory for use.
Please note the contraindications.
No liability for the operation or misuse of this device,
or any consequences thereof, in non-compliance
with the operation manual, will be assumed by the
manufacturer.

ga_fibroblast_pen_rev01_en 2

Purebeau Fibroblast Instruction Manual

Operating panel features

Figure 1: Powerbox

3 ga_fibroblast_pen_rev01_en

Purebeau Fibroblast Instruction Manual

Figure 2: Fibroblast Pen

Information and part names

1. Power LED
2. Connector cable with DS-2 plug, or 3.5mm jack

plug for connecting to a PMU device from
Purebeau New Cosmetics GmbH.
3. Trigger button
4. Head attachment
5. Applicator needle

ga_fibroblast_pen_rev01_en 4

Purebeau Fibroblast Instruction Manual

Technical information 10trs DS2

Type

Voltage supply 5-10V

Power consumption 1,75 VA

Pen weight 100g

Pen dimensions L 150mm
D 22mm

Compatible devices PUREBEAU I / MAGIC LINER
PUREBEAU LADYLINER
PUREBEAU II TRS250
Circle Pro

Operation

The "PUREBEAU Fibroblast" device was manufactured
in accordance with VDE regulations and is delivered to
the customer in physically impeccable condition. It should
only be operated in conjunction with a PMU device from
Purebeau New Cosmetics GmbH. The PMU device is to be
attached as quickly as possible to the output port of the

5 ga_fibroblast_pen_rev01_en

Purebeau Fibroblast Instruction Manual

Fibroblast pen in order for it to be operated.
Only the manufacturer or another authorised, technically
trained person authorised by the manufacturer may open the
device for maintenance and repairs.
The device should only be operated indoors and should be
used at an operating temperature of between 10°C and 35°C
in order to avoid impaired function.

Safety instructions - Contraindications

The "PUREBEAU Fibroblast" device must not be used in
case of any of the following, else there may be
detrimental health effects:

 fever
 heart complaints
 partial loss of sensation (a warning sign for pain)
 local inflammatory processes
 pregnancy
 neurological illnesses
 after consuming alcohol
 feeling unwell, or acute illness
 in any case of doubt, please consult your physician

before commencing treatment
 in the case of implanted devices (e.g. pacemakers)

Whenever the safe operation of the device can no longer be
assured, the device must be made inoperative and measures
taken to ensure against accidental operation.

It must be assumed that the device can no longer be used
safely if:

 the device shows visible signs of damage
 the device no longer functions

ga_fibroblast_pen_rev01_en 6

Purebeau Fibroblast Instruction Manual

 the device has been stored in poor conditions
 the device has been mishandled or exposed to

stresses during transport.
 has been brought from a very cold, into a warm place.

The condensation that forms on warming can
potentially damage the device. Leave the device to
warm up at room temperature before operating.
Regularly check the physical integrity of the device, e.g.
checking for damage to the outer casing. Repairs must only be
carried out at specialised repair centres.

Use

The PUREBEAU Fibroblast Pen is used for skin tightening. To
achieve this, a plasma is created by an electrical discharge
which acts by subliming the tissue at the application site. This
occurs in a limited area due to the very short burst of heat
input. Almost no heat is transmitted to the bordering tissues.
This selective subliming leads to an enhanced regeneration of
the entire treatment area, with the treatment being non-
aggressive due to its selectivity.
The pen is made ready for use by inserting the applicator into
the head attachment. Please push the applicator as far as
possible into the head attachment until it stops, and then
tighten the attachment cover by hand. Please do not use
any tools when tightening or loosening the attachment
cover.
To produce the electrical discharge, the pen must be
connected up to a Purebeau New Cosmetics PMU device. The
list of compatible devices can be found under the technical
information heading. The PMU device should be set to
maximum on the relevant channel.
Then, position the applicator around 1mmm above the
treatment area. Care must be taken when doing this to ensure
good stability and firm support in the treatment area.

7 ga_fibroblast_pen_rev01_en

Purebeau Fibroblast Instruction Manual

Then, press the trigger button (3). If the distance is correct, an
area of light appears and the treatment begins. Take care not
to apply the treatment for too long in any given area.

Replace the applicator after each use.

Cleaning and Maintenance

Before any cleaning or sterilising, the device must be
disconnected from the PMU device. Occasionally, the device
should be cleaned externally with a soft, lint-free cloth with a
weak disinfectant, if needed (e.g. a 50% water - 50% 1-
propanol solution).

All anodised surfaces and components of the FIBROBLAST
pen incl. accessories should be cleaned using a disinfectant
as specified by the DGHM, such as LYSETOL MED. Care
should be taken when selecting a disinfectant to ensure that it
is suitable for use on aluminium and that it meets hygiene
regulations.

-Follow the operator advice, and if necessary ask
the supplier for more information-

Function testing Repairs
Complaints

Errors: The pen does not function / the LED (1) does
not light up
Please check the connection from the Powerbox
Solution: to the PMU device. Please check whether the
PMU device functions correctly at maximum
speed with a PMU pen connected to the same
output.

Errors: The pen does not function / the LED (1) lights
up. Please check correct distance from the

Solution:

ga_fibroblast_pen_rev01_en 8

Purebeau Fibroblast Instruction Manual
applicator has been observed, and whether the
trigger button (3) has been operated correctly.
Check that the head attachment is firmly fitted.

If the handpiece still does not operate despite taking these
steps, please inform Purebeau New Cosmetics GmbH.

Hygiene instructions

The applicators for the Fibroblast pen are single-use only. As
such, it is vital that a new applicator is used for each customer.
The applicators should be disposed of in a dedicated waste
container after use.

Delivery contents

 Pen with Powerbox
 Instruction Manual
 5 sample applicators

9 ga_fibroblast_pen_rev01_en

Purebeau Fibroblast Instruction Manual

Guarantee policy

For the device: Purebeau Fibroblast 10trs DS2
Serial number

From the date of
purchase:

Until:

Stamp Signature

The manufacturer offers a 24-month guarantee covering
the entire device. Only guarantee claims based on
defects and malfunctions due to material faults and
manufacturing faults are covered.

Warning

The guarantee is void if unqualified or unauthorised
personnel attempt to repair the device, or in cases of
improper use.

ga_fibroblast_pen_rev01_en 10

Purebeau Fibroblast Instruction Manual

Manufacturer:
PUREBEAU NEW COSMETICS GmbH
Mozartstraße 12
13158 Berlin
Germany
www.purebeau-pro.com

11 ga_fibroblast_pen_rev01_en