e ngineer
NEW S LE T T ER
September 2022
DON’T MISS: ASPE SHOW GUIDE
WILLOUGHBY - SECURIT Y PRODUCTS + PRODUCT SELECTION
CODE CORNER: LEONARD VALVE - NEUTRON EMV ASSE 1071
ROCKFORD SEPARATORS - ABOUT GREASE TRAPS
HAWS - SAFET Y: AXION ADVANTAGE + CEU WEBINAR
S A L E S
G R O U P
CHICAGO
7623 PLAZA CT.
WILLOWBROOK, IL 60527
630.850.7750
PEORIA
8925 N PRAIRIE POINTE
PEORIA, IL 61615
309.693.7950
[email protected]
WWW.INLANDSALESGROUP.COM
Click here to view!
DOWNLOAD PDF GUIDE
SEP TEMBER 2022 1
willoughby security
WILLOUGHBY – A FAMILY-OWNED INDUSTRY LEADER IN STAINLESS STEEL SECURITY FIXTURES
Willoughby security products are designed to withstand daily use and abuse in a prison or other high-abuse environment.
Our fixtures are constructed from type 304, fully welded stainless steel that can withstand the harshest environments. We
offer the finest combination lavatory and toilet units, toilets, lavatories, urinals, showers, drinking fountains, bottle fillers,
detention accessories, and electronic water conservation controls available.
We have a wide array of fixtures in the Combination SKU’s
• Units in 15”, 18”, 20” and 26” widths for wall coverage
• ADA units in 37” and 49” Widths
• Ligature Resistant Units 1846 SERIES
• Plus, many more
4896 SERIES
Selecting the size is just the beginning.
Willoughby can adapt each project to what the owner
and facility wants for their installations. Will a multitude of options available the facility can predetermine what is important
to them or what is the best plan of action going forward.
Some of the most common options:
• Toilet orientation: L,R or Center ASHS-0013-6 LAV
• Pneumatic or Electronic Valving
• Waste Outlet sizing of 3” or 4” with a multitude of connection options
• 1.28GPM, 1.6 GPM or 3.5GPM flushometer options
• Overflow detection devices
• Tissue holders and towel hooks
• High Polish SS
• 12 Gauge cabinet
• Powder coat color – most common: white
• And much, much more...
WMSII WATER MANAGEMENT
Once we get the product selected the next most relevant option sold today
is the Willoughby WMSII Water Management System.
Willoughby electronic water conservation controls save new or existing facilities time, water, and money by taking plumbing
fixture water control from inmates and putting it back in the hands of corrections staff. Our devices are stand-alone
electronic modules designed to control the operation of electronic valves of a single fixture or a networked, computer-con-
trolled device designed to control multiple devices.
The net result can be a reduction in nuisance water usage and flooding, as well as an overall reduction in water and sewer
usage of up to 50% and eliminate inmate water usage issues forever.
SEP TEMBER 2022 2
Once outside the cell, we offer a multitude of other Stainless Steel fixtures for tough environments.
• Sinks and Lavatories
• Bottle fillers and drinking fountains
• Showers and Shower Bases
• Full line of Detention Accessories
US/KS 3636 SHOWER
WILLOUGHBY WEBSITE
WBF-1RM
Willoughby takes pride that, with very few exceptions, we produce all aspects of all of our products. We start with stainless
steel, resin, and plastics to craft the finest commercial/institutional plumbing products in the industry. Our facilities include
full CNC machining centers, manual and robotic welding departments, electronics manufacturing and assembly areas,
laser and plasma cutting, press brakes and draw presses, valve assembly stations, and a state-of-the-art solid surface
facility comprised of mixing, pouring, molding, and finishing areas.
THE WILLOUGHBY MANUFACTURING FACILITY IS CENTRALLY LOCATED AT 5105 W. 78TH STREET, INDIANAPOLIS, IN
46268. INDIANAPOLIS HAS BEEN OUR HOME SINCE OUR FIRST STEEL PRODUCT WAS SOLD IN 1947
BRIAN YELTON, CPMR
INLAND SALES GROUP
code corner SPEC SHEET
ASSE Certified 1071 ENV-6100-LF
The Specs:
-World’s First Digital Electronic High-Capacity Recirculation Ready Emergency Mixing Valve
-Self-Cleaning Using Leonard’s Proven Daily Sweep Feature
-Self-Balancing
-Alerts User When Maintenance is required (Valve Cleaning)
-1-1/4” Female Threaded NPT Inlet
-1-1/2” Female Threaded Outlet
-Rough Bronze Finish
-Integral Check/Stops on Inlets
-Low Lead Construction
-Internal Cold-Water Bypass of 40 GPM @30PSI on Loss of Hot
-Flowrate of 60 GPM @30PSI Drop
ASSE 1071 CERTIFICATION BRINGS ALONG A NO WORRY SPEC WITH PROVEN WINNING DIGITAL
TECHNOLOGY. EMV CAN EITHER BE INSTALLED ON A RECIRC LOOP OR AS A STAND ALONE VALVE.
CAPABLE OF HANDLING MULTIPLE SAFETY FIXTURES.
UPGRADE SAFET Y TO THE DIGITAL AGE!
SEP TEMBER 2022 3
rockford grease separators
SEPARATORS | INTERCEPTORS | CUSTOM BUILDS |
MANY TYPES OF WASTE SEPARATION
The following information contains excerpts that have been prepared as a guide for architects, building department officials,
engineers, health agencies, plumbing contractors, and others concerned with high standards of sanitation and construction.
GENERAL INFORMATION
A grease separator is a device designed and installed in the drain line to separate and retain various destructive, hazardous
and other undesirable matter from waterborne waste so that they may be periodically removed; thus preventing their
passage into the drainage system. Preventing grease from entering the sewer system (which results in clogging of laterals,
mains and disposal difficulties at treatment plants) can be accomplished by the installation of efficient grease separators at
the source of the grease.
SOME MAJOR POINTS WHERE GREASES ENTER THE SEWER SYSTEMS ARE:
1. Restaurants, cafeterias, hotels, hospitals and establishments with kitchen facilities.
2. Drains from soup kettles, stock kettles, meat, fish or fowl preparationin commercial facilities.
3. Animal slaughtering facilities, fowl, fish or meat packing establishments.
SEPARATORS FALL INTO TWO BASIC CATEGORIES:
Gravity Type Mechanical Type
SEPARATORS MAY BE CLASSIFIED FOR TWO TYPES OF OPERATIONS:
1. Intermittent flow operation is usually batch dumping, or periodic use for short periods.
2. Continuous flow operation is usually associated with manufacturing operations as in product processing installations. This
type of separator is usually large, either constructed of fabricated metal or poured-in-place concrete. The retaining of large
amounts of solids is normally ssociated with this type and must be taken into account in the design of such separators. The
removal of accumulated grease and solids must also be considered in the design and installation.
Besides grease, separators may be employed in separating and retaining numerous other wastes, such as precious metals,
glass chips and grindings, fibrous materials, metal chips, waxes, plaster, hair and lint, and others too numerous to mention. In
many instances, the product recovered by the separator more than pays for itself in salvage value. Also, the prevention of
clogged drain lines and the constant cost of rodding are eliminated. However, a simple means of removing these solids must
be incorporated in the design of the separator. Operation is based on grease tending to separate from water at low velocities of
flow; grease rises to the surface because of its low specific gravity, while water is discharged to the drainage system.
An effective separator must have a large enough cross-section so that the velocity of the flow through it does not
exceed the velocity at which the grease will separate. The flow of waste water must be evenly distributed over the
cross-section so that the maximum allowable velocity will not be exceeded at any point.
In designing drains and fixtures, present day methods produce high rates of flow. Ordinances have been revised to require
larger drain lines, and fixtures are designed to be “quick discharging, expediting the removal of wastes and preventing stop-
pages.
When entering a separator in small amounts at low rates of flow, grease is easily retained. Difficulties occur in fixtures capable
of discharging at high rates. However, a separator must be capable of efficiently handling the maximum discharge rate of the
fixture which it serves. When it is desirable to reduce the rate of flow to the separator, it should be done at the fixture outlet,
rather than at the separator inlet. Considerable velocity is attained in the drain line, depending on the length of the vertical
and/or horizontal run and other hydraulic conditions.
SEP TEMBER 2022 4
When the inlet is restricted, the waste water is jetted into the separator at high velocity. Since the velocity in the separator
must be low, there must be a great reduction of velocity at the inlet. This can be done by increasing the size of the inlet or by
an internal inlet baffle. The entrance velocity is more easily controlled when the inlet is low.
METHOD OF OPERATION
The exceptionally high efficiency of the Rockford Separator in retaining foreign waste matter in the unit is made possible by
its design for maximum water travel through the separator without turbulence and by the filtering action of its screens.
Note course of water travel in cut-open view. Arrows designate course from inlet, under and through separator screen and
flow-regulator filter screen, to outlet. There is no straight in-and-out travel from inlet to outlet. Note also separation and
retention, through gravity action, of lighter-than-water matter. The inlet closes when the separator’s holding capacity is
reached if the unit has been properly sized, installed correctly, and short circuiting devices and methods are not used.
A Rockford Separator has a built-in flow control;
it needs no external flow control.
TRAVEL OF WASTE WATER
Although it has the outward appearance of a straightthrough unit, there is
no straight in-and-out travel of waste water from inlet to outlet,
incorporating Rockford Separator standard features in maintaining
minimum turbulence, internal flow regulation through its filter screens,
and maximum length of water travel.
CONSTRUCTION
The Rockford Separator is built of all-welded heavy gauge steel for maximum structural strength and durability.
Gasketed cover is fastened to unit body by bolt assemblies, cross-tightened by hand to assure leakproof and airtight fit.
- The M units (straight through) have a non-removable separating screen and one filter screen to regulate flow and filter
waste water, making outside flow control or retarder unnecessary. The filter screen lifts out for easy cleaning of separator.
- The L and R units have a removable separating screen (U-shaped) and filter screen (V-shaped) that lift out for easy cleaning
of the unit. The slotted wall of the separator screen faces away from the inlet. The outlet is separated from main body of the
unit (accepted by all plumbing codes). This provides an outside visible trap seal which protects against entry of sewer air.
Outlet may be vented off vertical rise on tee or off horizontal run from unit. Standard tapped inlet and outlet are furnished.
COR-TEN® INFORMATION
Cor-Ten® high-strength, low carbon steel with its high strength and outstanding resistance to atmospheric corrosion is
available where maintenance cost savings are prime considerations. Even in an unpainted condition, Cor-Ten® has a tightly
adherent oxide surface which stops further oxidation. Painted or coated, this characteristic is further enhanced. The reliability
and strength of this material has been proven in many applications, such as railroad cars, bridges and two of the tallest
buildings in the world: the John Hancock Building and the Sears Tower in Chicago.
LOCATION OF SEPARATOR
When deciding on the location for the separator, be sure there is headroom to lift out the screens for cleaning; otherwise use
flush-with-floor model. Locate separator as close to fixture as possible. Venting is necessary on outlet leg to prevent
siphonage. On larger models with internal rear vent, the separator body must be vented. Comply with local code require-
ments on all installations of separators.
ROB WILLIAMS
PRESIDENT
ROCKFORD SEPARATORS
SEP TEMBER 2022 5
safety
HAWS AXION TECHNOLOGY
Haws uses the Axion Technology throughout its Safety line.
What does that mean for you’re the specifier or the end user? 7260BT-7270BT
The best most complete safety eye/face wash on the market.
The Axion Head is a single head that encompasses the EYE and FACE wash combined with 4 integrated
outlets. This eliminates you from having to determine if you need an eye wash and/or an eye/face wash.
Key benefits include:
- Achieves Immediate ANSI Compliance Solves the Most Common Flow Issues
- AXION eye/face wash and shower heads can 1. Simultaneous Flow
immediately solve common compliance issues 2. Non-Injurious Controlled Flow
related to simultaneous and controlled flow. 3. Even Eyewash Flow Patterns
- Cost-Effective Solution
- Kits can be installed on the spot at a significantly
lower cost than replacing an entire unit. AXION LITERATURE HAWS SAFETY
As you look through the safety line you will see this Axion head in all Haws configurations. Medically superior
AXION MSR design and technology improves existing emergency eyewash and shower equipment with the
optimal victim comfort solution while maintaining ANSI compliance.*
AXION's revolutionary inverted water flow design sweeps
contaminants away from the interior of the eye and vulnerable
nasal cavity. This makes AXION the only eyewash system repli-
cating standard medical protocols and the natural function of the
human eye.
The AXION head can also be retrofitted onto all competitor’s
product.
CLICK IMAGE BELOW TO REGISTER!
FREE CEU WEBINAR
WEDNESDAY, OCT. 12, 2022 | 10:00-11:00 AM PST
A COMPREHENSIVE GUIDE TO ANSI/ISEA Z358.1
AND EMERGENCY SHOWER/EYEWASH COMPLIANCE
While the majority of business owners believe that their emergency equipment is
fully functional, the reality is that there is a one in five chance they will work
properly in an actual emergency. By attending this free webinar you will gain a
better understanding of the ANSI/ISEA Z358.1 Standard for eyewash and shower
equipment, along with a step-by-step overview on how to test your equipment for
installation and performance compliance to ensure you are prepared during an
actual emergency.
SEP TEMBER 2022 6
AXION Advantage®
Achieve Compliance and
Solve Your Most Common
Emergency Eye/Face Wash &
Shower Flow Problems with
a Haws® AXION® Retrofit Kit
APPLICATION: Pedestal and Wall-Mount Eyewashes
to mitigate your most common flow problems, including:
Lack of Simultaneous Flow
When installed together, the AXION® MSR eye/face wash
a consistent flow rate that meets simultaneous flow AX13 AX13S
requirements.
Lack of Controlled Non-Injurious Flow APPLICATION: Combination Showers
AXION® MSR products provide laminar flow eye/face wash
streams for even, consistent, predictable stream height and
circumference for greater user comfort, encouraging use
for the full 15-minute ANSI Z358.1 requirement.
Uneven Flow Pattern
AXION® MSR provides a controlled flow to both eyes
simultaneously with comfortable water pressure.
AX14 AX14S
AXION® provides compliance on the spot at a significantly
lower cost than replacing an entire unit. With included parts, APPLICATION: Halo Wall and APPLICATION: Lab and Hose Units
AXION® retrofit kits convert 80% of existing competitor units Pedestal-Mounted Retrofit
and can update them from a face wash to an eye/face wash,
ensuring full eye and face flushing.
Leveraging Haws patented technology, AXION® provides
laminar flow and an inverted water stream to ensure
increased victim comfort while sweeping contaminants
away from the eye. AX15 AX16
www.hawsco.com • 1.888.640.4297
©2021 Haws Corporation • All rights reserved