Issue Date: July 2017 Fixture/Location Ref: Project Ref:
ProSpex 4.25” Pinhole
Pinhole Downlight
The ProSpex 4.25” Pinhole, forms part of our extensive range of Flanged or
Flangeless downlights, available in fixed and adjustable variants.The range also includes
a Washlight version, all available for many MR16 sized light sources including Lucent’s
own LED50 series of modules.
• 1.57” (40mm) diameter pinhole aperture
• Deep regressed lamp position for minimal glare
• Accepts up to 2 media accessories
• Damp location version available
• Easy rotation and re-lamping
• Textured White and Black finishes to trim as standard
• Other trim finishes available to special order
• Family of matching products also available
Flanged
Pinhole Fixed Flanged Pinhole Accent Flanged
A30413-F-LED-PB
• Ceiling kit with overlap flange A30413-A-LED-PB
• Fixed Version • Ceiling kit with overlap flange
• 360° rotation
Flangeless • 35° tilt
• Adjustable Version
Pinhole Fixed Flangeless Pinhole Accent Flangeless
A30413-F-LED-PC A30413-A-LED-PC
• Mud-in kit for seamless flush finish • Mud-in kit for seamless flush finish
• Fixed Version • 360° rotation
• 35° tilt
• Adjustable Version
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 01
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Photometric Diagrams
LED50 ONE GEN2
LED51/2-930-12 LED51/2-930-24 LED51/2-930-38
LED51/2, 3000K, 12° LED51/2, 3000K, 24° LED51/2, 3000K, 38°
Information*
LED Type 12° Cree COB 38° 12° Cree COB 38°
CCT 1075 2700K 1200 1014 3000K 1085
Drive Current 598 350mA 580 767 350mA 744
Power inc Driver 7905 13.8W 1717 10134 13.8W 2201
Beam Angle 60 24° 58 55 24° 53
Source Lumens 56 1084 56 57 1021 57
Delivered Lumens 90.8 643 90.8 90.3 824 90.3
Intensisty cd 6525 8366
Efficacy lm/w 64 59
R9 56 57
TM30 90.8 90.3
Forward Volt 36V 36V
CRI ≥90 CRI ≥90 CRI
*Data correct at time of publishing
LED Module Order Code: LED51/2
Lamp LED50 ONE
90 CRI 2700K
LED51/2 90 CRI 3000K
90 CRI 4000K
CCT
927
930
940
Beam 12°
24°
12 38°
24
38
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 02
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Photometric Diagrams
LED50 ONE Super Spot
LED51SS-927-7 LED51SS-930-7
LED51SS, 2700K, 7° LED51SS, 3000K, 7°
Information*
LED Type XHP XHP
CCT 3000K 3000K
Drive Current 350mA 500mA
Power inc Driver 4.75W 6.75W
Beam Angle
Source Lumens 7° 7°
Delivered Lumens 372 471
Intensisty cd 316 405
Efficacy lm/w 12743 16209
R9 67 60
TM30 55 55
Forward Volt 90.6 90.6
CRI 11.5V 11.5V
≥90 CRI ≥90 CRI
*Data correct at time of publishing
LED Module Order Code: LED51SS 7
Lamp LED50 ONE Super Spot
90 CRI 2700K
LED51SS 90 CRI 3000K
CCT
927
930
Beam
7 7°
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 03
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Photometric Diagrams
LED50 GEN2
LED50/2-830-18 LED50/2-830-22 LED50/2-830-36
LED50 GEN2, 3000K, 18° LED50 GEN2, 3000K, 22° LED50 GEN2, 3000K, 36°
Information*
LED Type 18° XP-E2 36° 18° XP-E2 36°
CCT 882 3000K 807 1102 3000K 1042
Drive Current 598 350mA 580 767 500mA 744
Power inc Driver 7905 10W 1717 10134 14W 2201
Beam Angle 60 58 55 53
Source Lumens 10.5 22° 10.5 10.5 22° 10.5
Delivered Lumens 82.4 910 82.4 82.4 1133 82.4
Intensisty cd 643 824
Efficacy lm/w 6525 8366
R9 64 59
TM30 10.5 10.5
Forward Volt 82.4 82.4
CRI 27V 27V
≥80 CRI ≥80 CRI
*Data correct at time of publishing
LED Module Order Code: LED50/2
Lamp LED50 GEN2
80 CRI 2700K
LED50/2 80 CRI 3000K
80 CRI 4000K
CCT
827
830
840
Beam 18°
22°
18 36°
22
36
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 04
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Photometric Diagrams
LED50 PLUS GEN2
LED50PLUS/2-930-18 LED50PLUS/2-930-22 LED50PLUS/2-930-36
LED50 Plus GEN2, 3000K, 18° LED50 Plus GEN2, 3000K, 22° LED50 Plus GEN2, 3000K, 36°
Information*
LED Type 18° XP-E2 36° 18° XP-E2 36°
CCT 925 3000K 845 1250 3000K 1135
Drive Current 700 350mA 510 929 500mA 676
Power inc Driver 9781 10W 1200 5014 14W 1592
Beam Angle 70 51 66 48
Source Lumens 62.2 22° 62.2 62.2 22° 62.2
Delivered Lumens 91.2 959 91.2 91.2 1303 91.2
Intensisty cd 706 937
Efficacy lm/w 3326 4411
R9 71 67
TM30 62.2 62.2
Forward Volt 91.2 91.2
CRI 27V 27V
≥90 CRI ≥90 CRI
*Data correct at time of publishing
LED Module Order Code: LED50PLUS/2
Lamp LED50 PLUS GEN2
LED50PLUS/2
CCT 90 CRI 2700K
90 CRI 3000K
927
930
Beam 18°
22°
18 36°
22
36
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 05
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Fixture Order Code: A30413
Fixture 4.25” Pinhole Downlight
A30413
Type
F Fixed
A Accent
LED LED50 GEN2
LED50 GEN2 PLUS
LED50/2 LED50 ONE GEN2
LED50/2-90 LED50 SuperSpot
LED51/2
LED51SS
Flange
TR Flange
TL Flangeless
Finish White
Black
WH Special Color
BK
RAL
Ceiling Thickness
12 1/2”
58 5/8”
75 3/4”
C Custom
Location
DP Damp
Media at LED
(Blank) None
Louvre
LL45 Honeycomb
Lens
LLDF Solite
LLFR Frosted
LLLS Linear Spread
LLHS Heavy Spread
LLCC Warm Tone
LLUV UV
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 06
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Driver Information
Manufacturer Driver Input Voltage Mains Frequency Dimming Range Output Power Efficacy Current Ambient Temp
Harvard CLK33 0-10V
EldoLED EldoLED DALI 120-277VAC 47-63Hz 100%-1% 11-33W 85% 100 - 1050mA -25°C - 50°C
EldoLED EldoLED 0-10V
Lutron Hi-Lume Phase 120-277VAC 50-60Hz 100%-0% 30W 84% 200-1050mA -20°C - 50°C
Harvard CL Standard
Lutron Hi-Lume EcoSystem 120-277VAC 50-60Hz 100%-0% 30W 84% 150-1400mA -20°C - 50°C
120VAC 50-60Hz 100%-1% 2-48W 79% 350-700mA -20°C - 50°C
120-277VAC 47-63Hz N/A 9-33W 87% 350 - 1000mA -25°C - 40°C
120-277VAC 50-60Hz 100%-1% 2-48W 81% 350-700mA -20°C - 50°C
Emergency: EM
Driver 5 Watts
CP05 7 Watts
CP07 12 Watts
CP12
CP05: 120-277VAC, 50/60Hz
Input Voltage
Input Rating 2.7 Watts (max)
Output Voltage Range
Output Current 10-60VDC Class 2 Compliant
Output Power
Power Factor 0.5A (@10VDC) - 0.08A (@60VDC)
Emergency Operation
5 Watts
≥ 0.9
90 Minutes
CP07: 120-277VAC, 50/60Hz
Input Voltage
Input Rating 3.5 Watts (max)
Output Voltage Range
Output Current 10-60VDC Class 2 Compliant
Output Power
Power Factor 0.7A (@10VDC) - 0.12A (@60VDC)
Emergency Operation
7 Watts
≥ 0.9
90 Minutes
CP12: 120-277VAC, 50/60Hz
Input Voltage
Input Rating 5.0 Watts (max)
Output Voltage Range
Output Current 10-60VDC Class 2 Compliant
Output Power
Power Factor 1.2A (@10VDC) - 0.2A (@60VDC)
Emergency Operation
12 Watts
≥ 0.9
90 Minutes
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 07
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Issue Date: March 2017 LMT(LED50 Range)
ProSpex Mounting Tray for
Non Insulated Ceiling
For Lucent LED50 Range LED Module
Lucent’s range of ProSpex Downlights are designed to work in various ceiling LED51/2 LED50/2 LED51SS
type installations, trim or trimless. LED50/2-90
Housing Description
• Rigidly constructed
• Fabricated from steel
• Adjustable steel hanging bars, adjustment between 9-15.25"/14-24”
• Includes wiring/junction box
• All connections accessible through ixture aperture
• Supplied complete with LED driver
Housing Order Code: LMT 13" NIC
Lucent Mounting Tray
Mounting Tray Size
13"
Housing Type
NIC Non-Insulated Ceiling
Mounting Hardware
9” to 15.25”
14 14” to 24”
LED LED50 GEN2
LED50/2
LED50/2PLUS LED50 GEN2 PLUS
LED51/2 LED50 ONE GEN2 (350mA MAX ONLY)
LED51SS LED50 ONE SuperSpot
Drive Current
350 350mA
500 500mA
Supply Voltage
120 120V
277 277V
Protocol
S Non-Dimmable LAE Lutron A Series 3-Wire
P TRIAC/Phase (120V ONLY) A Analog
LP Lutron Phase 2-Wire (120V ONLY) ED EldoLED DALI
ESS Eco System 5 Series EA EldoLED Analog
LHE Lutron H Series Fade to Black
Copyright © 2014 Lucent Lighting Inc. Tel. New York: +1 518 239 5100
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Installation Instructions for flange fitting with tray ! MAINS POWER TO BE SWITCHED OFF
DURING INSTALLATION.
For Insulated and Non-Insulated Ceiling type installations
1. Fixing of tray C 3. Finish ceiling face 4. Paint and allow to dry fully
2. Plasterboard installation
Cutout (C): Ø4” (103.0mm)
5. Trim kit installtion 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation
9. Align fixture with trim kit and 10. Finished Installation
install then install front plate
Fixture Adjustment Instructions
1. Remove fixture from trim kit and 2. Adjust tilt 3. Replace fixture in trim kit
adjust rotation
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 08
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Installation Instructions for flangeless fitting with tray ! MAINS POWER TO BE SWITCHED OFF
DURING INSTALLATION.
For Insulated and Non-Insulated Ceiling type installations
1. Fixing of tray C 3. Trimless mud in kit installtion 4. Mud in and allow to dry fully
2. Plasterboard installation
Cutout: Ø3.85” (98mm)
5. Paint and allow to dry fully 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation
9. Align fixture with trimless kit and 10. Finished Installation
install then install front plate
Fixture Adjustment Instructions
1. Remove fixture from trimless kit 2. Adjust tilt 3. Replace fixture in trimless kit
and adjust rotation
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 09
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Issue Date: April 2016 LH-6.75 (LED50 Series)
ProSpex 6.75” Housing
For Lucent LED50 Series Modules
Lucent’s range of ProSpex Downlights are designed to work in various ceiling LED51/2 LED50/2 LED51SS
type installations, trim or trimless. LED50/2-90
We offer housings for Insulated and Non-Insulated Ceilings as well as Airtight
types.
L2 Housing Description
WL
• Rigidly constructed
• Easy installation, refer to installation instructions
• Fabricated from sheet steel
• All parts finished in black
• Lockable, adjustable steel bar hangers or butterfly/caterpillar
bracket mounting options
• Includes wiring/junction box
• All connections accessible through fixture aperture
• Supplied complete with driver where required
H
L1 W1
Housing Dimensions
H L L1 L2 W W1
6.75” 11.75” 14.95” 15.35” 8.75” 14.00” to 24.00”
Housing Order Code: LH 6.75 NIC
Height 6 3/4”
Non-Insulated Ceiling
6.75
Housing Type
NIC
Mounting Hardware
14 14” to 24”
BB Butterfly Bracket
CB Caterpillar Bracket
LED
LED50 GEN2
LED50/2
LED50/2PLUS LED50 GEN2 Plus
LED50 One GEN2 (350mA ONLY)
LED51/2 LED50 One SuperSpot
LED51SS
Drive Current
350 350mA
500 500mA
Supply Voltage
120 120V
277 277V
Protocol
S Non-Dimmable
P TRIAC/Phase (120V ONLY) LAE Lutron A Series 3-Wire
A Analog
LP Lutron Phase 2-Wire (120V ONLY) ED EldoLED DALI
ESS Eco System 5 Series EA EldoLED Analog
LHE Lutron H Series Fade to Black
IC,ATC and UATC Housing Types – Can be installed in direct contact with insulation when insulation R-Value is no greater than
60. NIC Housing Type – No contact with insulation and at least 3 inches spacing from insulation in all directions.
Copyright © 2014 Lucent Lighting Inc. Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Issue Date: January 2017 LH-8.50 (LED50 Series)
ProSpex 8.50” Housing LED51/2 LED50/2 LED51SS
LED50/2-90
IC/Airtight, CCEA
For Lucent LED50 Series Modules Housing Description
Lucent’s range of ProSpex Downlights are designed to work in various • Rigidly constructed
ceiling type installations, trim or trimless. • Easy installation, refer to installation instructions
We offer housings for Insulated and Non-Insulated Ceilings as well as • Fabricated from sheet steel
Airtight types. • All parts finished in black
• Lockable, adjustable steel bar hangers or butterfly/caterpillar
L2
WL bracket mounting options
• Includes wiring/junction box
• All connections accessible through fixture aperture
• Supplied complete with driver where required
H
L1 W1
Housing Dimensions
H L L1 L2 W W1
8.50” 15.75” 18.95 19.30” 12.00” 14.00” to 24.00”
Housing Order Code: LH 8.50
Height
8.50 8 1/2”
Housing Type
IC Insulated Ceiling
AT Airtight, CCEA
Mounting Hardware
14 14” to 24”
BB Butterfly Bracket
CB Caterpillar Bracket
LED
LED50 GEN2
LED50/2
LED50/2PLUS LED50 GEN2 Plus
LED50 One GEN2 (350mA ONLY)
LED51/2 LED50 One SuperSpot
LED51SS
Drive Current
350 350mA
500 500mA
Supply Voltage
120 120V
277 277V
Protocol
S Non-Dimmable
P TRIAC/Phase (120V ONLY) LAE Lutron A Series 3-Wire
A Analog
LP Lutron Phase 2-Wire (120V ONLY) ED EldoLED DALI
ESS Eco System 5 Series EA EldoLED Analog
LHE Lutron H Series Fade to Black
IC,ATC and UATC Housing Types – Can be installed in direct contact with insulation when insulation R-Value is no greater than
60. NIC Housing Type – No contact with insulation and at least 3 inches spacing from insulation in all directions.
Copyright © 2014 Lucent Lighting Inc. Tel. NewYork: +1 518 239 8300
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Issue Date: January 2017 LH-11.25 (LED50 Series)
ProSpex 11.25” Housing LED51/2 LED50/2 LED51SS
LED50/2-90
IC/Airtight, CCEA
For Lucent LED50 Series Modules Housing Description
Lucent’s range of ProSpex Downlights are designed to work in various • Rigidly constructed
ceiling type installations, trim or trimless. • Easy installation, refer to installation instructions
We offer housings for Insulated and Non-Insulated Ceilings as well as • Fabricated from sheet steel
Airtight types. • All parts finished in black
• Lockable, adjustable steel bar hangers or butterfly/caterpillar
L2
WL bracket mounting options
• Includes wiring/junction box
• All connections accessible through fixture aperture
• Supplied complete with driver where required
H
L1 W1
Housing Dimensions
H L L1 L2 W W1
11.25” 15.75” 18.95 19.30” 12.00” 14.00” to 24.00”
Housing Order Code: LH 11.25
Height
11.25 11 1/4”
Housing Type
IC Insulated Ceiling
AT Airtight, CCEA
Mounting Hardware
14 14” to 24”
BB Butterfly Bracket
CB Caterpillar Bracket
LED
LED50 GEN2
LED50/2
LED50/2PLUS LED50 GEN2 Plus
LED50 One GEN2 (350mA ONLY)
LED51/2 LED50 One SuperSpot
LED51SS
Drive Current
350 350mA
500 500mA
Supply Voltage
120 120V
277 277V
Protocol
S Non-Dimmable
P TRIAC/Phase (120V ONLY) LAE Lutron A Series 3-Wire
A Analog
LP Lutron Phase 2-Wire (120V ONLY) ED EldoLED DALI
ESS Eco System 5 Series EA EldoLED Analog
LHE Lutron H Series Fade to Black
IC,ATC and UATC Housing Types – Can be installed in direct contact with insulation when insulation R-Value is no greater than
60. NIC Housing Type – No contact with insulation and at least 3 inches spacing from insulation in all directions.
Copyright © 2014 Lucent Lighting Inc. Tel. NewYork: +1 518 239 8300
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Installation Instructions for flange fitting with housing ! MAINS POWER TO BE SWITCHED OFF
DURING INSTALLATION.
For Insulated and Non-Insulated Ceiling type installations
1. Fixing of housing C 3. Finish ceiling face 4. Paint and allow to dry fully
2. Plasterboard installation
Cutout (C): Ø4” (103.0mm)
5. Trim kit installtion 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation
9. Align fixture with trim kit and 10. Finished Installation
install then install front plate
Fixture Adjustment Instructions
1. Remove fixture from trim kit and 2. Adjust tilt 3. Replace fixture in trim kit
adjust rotation
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 10
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com
Installation Instructions for flangeless fitting with housing
For Insulated and Non-Insulated Ceiling type installations ! MAINS POWER TO BE SWITCHED OFF
DURING INSTALLATION.
1. Fixing of housing C 3. Trimless mud in kit installtion 4. Mud in and allow to dry fully
2. Plasterboard installation
Cutout: Ø3.85” (98mm)
5. Paint and allow to dry fully 6. Dropdown of power supply 7. Fixture wiring connection 8. Power supply re-installation
9. Align fixture with trimless kit and 10. Finished Installation
install then install front plate
Fixture Adjustment Instructions
1. Remove fixture from trimless kit 2. Adjust tilt 3. Replace fixture in trimless kit
and adjust rotation
Copyright © 2015 Lucent Lighting Inc. Tel. New York: +1 518 239 8300 Page 11
Tel. London: +44 (0)20 8442 0880
www.lucent-lighting.us.com