Low Voltage & Wiring Brochure

Low Voltage & Wiring Brochure

Keywords: LV Cables

50


Conductor Type (Class) 51


Conductor Type (Class) 52


Conductor Type (Class) 53


Conductor Type (Class) 54


Conductor Type (Class) 55


56


Conductor Type (Class) 57


Conductor Type (Class) 58


Conductor Type (Class) 59


Conductor Type (Class) 60


Conductor Type (Class) 61


62


63 Conductor Type (Class)


64 Conductor Type (Class)


65 Conductor Type (Class)


66 Conductor Type (Class)


70 For Main Distribution Board (MDB) Wiring BSEN50525-2-31 IEC 60228 Class 5 BSEN50525-2-31 67 DRAKA 300/500V CU/PVC 70˚C BS EN 50525-2-31 HO5V-K 1X (SIZE) MM2 0.5mm2 -1mm2


68 For Main Distribution Board (MDB) Wiring BSEN50525-2-31 IEC 60228 Class 5 DRAKA 450/750V CU/PVC 70˚C BSEN 50525-2-31 HO7V-k1 X (SIZE) MM2


Soft Drawn Copper Wires 70


Solar PV Cables AD8 Certified


PRYSUN H1Z2Z2-K cables are designed and tested acc. to EN50618:2014, intended for the interconnection of various elements in photovoltaic systems, including panel interconnection, between panels and string boxes or from string boxes to the inverter. They are suitable for applications in/at equipment with protective insulation and may be installed as fixed or freely suspended or free movable, indoor or outdoor. Installation in cable trays, conduits, on and in walls is permissible. APPLICATION DESIGN & CONSTRUCTION Conductor Class 5 Tinned copper conductor Insulation Halogen free cross-linked elastomer Natural color – white or red Outer Sheath Halogen free cross-linked elastomer Anti-Rodent or Anti-Termite (optional) Outer Sheath Color Black or Red ELECTRICAL PARAMETERS Standards EN 50618:2014 Rated Voltage 1.5/1.5kV DC 1.0/1.0kV AC Max. Permissible Operating Voltage 1.8/1.8kV DC 1.2/1.2kV AC Voltage Tests (5 mins) 15kV DC 6.5kV AC Electrical Tests Acc. to EN 50618, Table 2: - Conductor Resistance; - Voltage Test on completed cable (AC and DC); - Spark Test on insulation; Insulation resistance (at 20˚C and 90˚C in water); - Insulation Long-Term Resistance to DC (10 days, in 85˚C water, 1.8kV DC); - Surface Resistance of Sheath. THERMAL PARAMETERS Max. Operating Temperature Max. 90°C at the conductor 20,000 hours at max. conductor temp. of 120°C, with 90°C ambient temp. Max. Short Circuit Temperature 250°C at the conductor (5s.) Ambient Temperature Installation and handling: -25°C up to +60°C In operation: -40°C up to +90°C Resistance to Cold Acc. to EN 50618, Table 2: - Cold Bending Test at -40°C acc. to EN 60811-504; - Cold Elongation Test at -40°C acc. to EN 60811-505; - Cold Impact Test at -40°C acc. to EN 60811-506 and EN 50618 Annex C. Damp-Heat Test Acc. to EN 50618, Table 2: - 1,000 hours at 90°C and 85% humidity per EN 60068-2-78 SEA 01/2023 OPTIONAL HF HALOGEN FREE 73 SOLAR PV CABLE PRYSUN™ H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Elastomer Insulated Per EN50618 Section 4 Solar PV Cables


PRYSUN™ H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Elastomer Insulated Per EN50618 SOLAR PV CABLE 74


75 SOLAR PV CABLE PRYSUN™ H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Elastomer Insulated Per EN50618 TECHNICAL PARAMETERS Number of Cores x Cross Section * Outer Diameter Range Approx. Cable Weight Minimum Bending Radius Min. Insulation Resistance at 20˚C Max. Conductor Resistance at 20˚C DC Current carrying capacity ** Voltage Single Drop cable free in air Single cable On a surface Two loaded Cables touching, on a surface [mm²] [mm] [kg/km] [MΩ.km] [Ω/km] [A] [A] [A] [mV/A/m] 1 x 1.5 4.4 – 5.2 35 6D 860 13.7 30 29 24 38.167 1 x 2.5 4.9 – 5.7 47 6D 690 8.21 41 39 33 22.871 1 x 4 5.4 – 6.2 61 6D 580 5.09 55 52 44 14.180 1 x 6 5.9 – 6.4 81 6D 500 3.39 70 67 57 9.444 1 x 10 7.1 – 7.8 123 6D 420 1.95 98 93 79 5.433 1 x 16 9.0 – 9.8 189 6D 340 1.24 132 125 107 3.455 1 x 25 10.4 – 11.5 288 6D 340 0.795 176 167 142 2.215 1 x 35 11.7 – 12.8 379 6D 290 0.565 218 207 176 1.574 1 x 50 13.5 – 14.5 535 6D 270 0.393 276 262 221 1.095 1 x 70 15.5 – 16.5 745 6D 250 0.277 347 330 278 0.772 1 x 95 17.7 – 18.7 965 6D 220 0.210 416 395 333 0.585 1 x 120 19.2 – 20.4 1211 6D 210 0.164 48 464 390 0.457 1 x 150 21.4 – 22.6 11481 6D 210 0.132 566 53 453 0.368 1 x 185 23.7 – 25.1 1822 6D 200 0.108 644 612 515 0.301 1 x 240 27.1 – 28.5 2353 6D 200 0.0817 775 736 620 0.228 * Other sections may be available upon request. ** Ambient Temperature: 60˚C. Maximum conductor Temperature: 120˚C Values are subject to manufacturing tolerances. SEA 01/2023


77 SOLAR PV CABLE TECSUN H1Z2Z2-K cables were designed and tested acc. to EN50618. They are suitable for applications and/or outdoor, in industrial and agriculture field, in/at equipment with protective insulation (Protecting Class II), and in explosion hazard areas (Prysmian Internal Testing). Prysmian TECSUN H1Z2Z2-K cables are suitable for direct burial (Prysmian Internal Testing), where the corresponding guidelines shall be considered. APPLICATION TECSUN™ - H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Rubber Insulated Per EN50618 DESIGN & CONSTRUCTION Conductor Electrolytic Tinned copper, finely stranded Class 5 acc. to IEC 60228 Insulation Cross-linked HEPR 120˚C Outer Sheath Cross-linked EVA rubber 120˚C Anti-Rodent or Anti-Termite (optional) Outer Sheath Color Black ELECTRICAL PARAMETERS Standards EN 50618:2014 Rated Voltage 1.5/1.5kV DC 1.0/1.0kV AC Max. Permissible Operating Voltage 1.8/1.8kV DC 1.2/1.2kV AC Voltage Tests (5 mins) 15kV DC 6.5kV AC Electrical Tests Acc. to EN 50618, Table 2: - Conductor Resistance; - Voltage Test on completed cable (AC and DC); - Spark Test on insulation; Insulation resistance (at 20˚C and 90˚C in water); - Insulation Long-Term Resistance to DC (10 days, in 85˚C water, 1.8kV DC); - Surface Resistance of Sheath. PRYSMIAN internal test: - Dielectric Strength; Insulation Resistance at 120˚C in air. THERMAL PARAMETERS Max. Operating Temperature Max. 90°C at the conductor (lifetime acc. To Arrhenius-Diagram = 30 years). 20,000 hours of operation at max. conductor temperature of 120°C Max. Short Circuit Temperature 250°C at the conductor (5s.) Ambient Temperature Installation and handling: -25°C up to +60°C In operation: -40°C up to +90°C Resistance to Cold Acc. to EN 50618, Table 2: - Cold Bending Test at -40°C acc. to EN 60811-504; - Cold Elongation Test at -40°C acc. to EN 60811-505; - Cold Impact Test at -40°C acc. to EN 60811-506 and EN 50618 Annex C. Damp-Heat Test Acc. to EN 50618, Table 2: - 1,000 hours at 90°C and 85% humidity (test acc. to EN 60068-2-78). SEA 01/2023 EVA RUBBER 120˚C OPTIONAL


MECHANICAL PARAMETERS Max. Tensile Load 15 N/mm² in operation, 50 N/mm² during installation Min. Bending Radius Acc. to EN 50565-1 Abrasion Resistance PRYSMIAN internal test: - Acc. To DIN ISO 4649 against abrasive paper; - Sheath against sheath; - Sheath against metal; - Sheath against plastics. Shrinkage Test Acc. to EN 50618, Table 2: - Max. Shrinkage <2% (test acc. To EN 60811-503). Pressure Test at High Temperature PRYSMIAN internal test: - <50% acc. to EN 60811-508. Dynamic Penetration Test Acc. to EN 50618 Annex D: - Meets requirements of EN 50618. Shore-Hardness PRYSMIAN internal test: - Type A: 85 acc. to DIN EN ISO 868. Durability of Print Acc. to EN 50618: - Test acc. to EN 50396. Rodent Resistance Safety can be optimized by utilizing protective hoses, or protective element, such as a metallic screen braid. TECSUN™ - H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Rubber Insulated Per EN50618 CHEMICAL PARAMETERS Reaction to Fire Acc. to EN 50618, Table 2: - Single Cable Flame Test per EN 60332-1-2; - Low Smoke Emission per EN 61034-2 (Light Transmittance >70%); - Halogen-free per EN 50525-1 Annex B. PRYSMIAN internal test: - Multiple Cable Flame Test per EN 50305-9; - Low Toxicity per EN 50305 (ITC < 3). Resistance to Oil PRYSMIAN internal test, on sheath: - 24h, 100°C (meets VDE 0473-811-404, EN 60811-404). Weather Resistance Acc. to EN 50618, Annex E and Table 2: - UV Resistance on sheath: tensile strength and elongation at break after 720h (360 Cycles) of exposure to UV lights acc. to EN 50289-4-17, Method A; - Ozone Resistance: per Test Type B (DIN EN 50396). PRYSMIAN internal test: - Water Absorption (Gravimetric) per DIN EN 60811-402. Water Resistance 92 weeks long-term test in 90˚C water Acid and Alkaline Resistance Acc. to EN 50618, Annex B: - 7 days, 23°C (N-Oxalic Acid, N-Sodium Hydroxide) acc. to EN 60811-404. Ammonia Resistance PRYSMIAN internal test: - 30 days in Saturated Ammonia Atmosphere. Environmentally Friendly TECSUN cables comply with the RoHS directive 2011/65/EU. SEA 01/2023 SOLAR PV CABLE 78


79 SOLAR PV CABLE TECSUN™ - H1Z2Z2-K 1/1kV AC (1.5/1.5kV DC) Photovoltaic Cable, Rubber Insulated Per EN50618 TECHNICAL PARAMETERS Cores x Cross Section Maximum Conductor Diameter Outer Diameter Bending Radius Approx. Weight Maximum Permissible Tensile Force Maximum Conductor Resistance at 20˚C Current Carrying Capacity Short Circuit Current (1s from 90˚C - 250˚C) Single Cable in free air (60˚C ambient Temp.) Single Cable on surface (60˚C ambient Temp.) [C x mm²] [mm] [mm] [mm] [kg/km] [N] Ω/km A A kA 1 x 1.5 1.6 4.4 – 5.2 15 35 23 13.7 30 29 0.21 1 x 2.5 1.9 4.9 – 5.7 17 46 38 8.21 41 39 0.36 1 x 4 2.4 5.4 – 6.2 18 61 60 5.09 55 52 0.57 1 x 6 2.9 5.9 – 6.7 20 80 90 3.39 70 67 0.86 1 x 10 4 7.1 – 7.8 23 122 150 1.95 98 93 1.43 1 x 16 5.6 9 – 9.8 30 200 240 1.24 132 125 2.29 1 x 25 6.4 10.4 – 11.5 34 290 375 0.795 176 167 3.58 1 x 35 7.5 11.7 – 12.8 50 400 525 0.565 218 207 5.01 1 x 50 9 13.5 – 14.5 58 560 750 0.393 276 262 7.15 1 x 70 10.8 15.5 – 16.5 66 750 1050 0.277 347 330 10.01 1 x 95 12.6 17.7 – 18.7 75 970 1425 0.21 416 395 13.59 1 x 120 14.2 19.2 – 20.4 82 1220 1800 0.164 488 464 17.16 1 x 150 15.8 21.4 – 22.6 91 1500 2250 0.132 566 538 21.45 1 x 185 17.4 23.7 – 25.1 101 1840 2775 0.108 644 612 26.46 1 x 240 20.4 27.1 – 28.5 114 2400 3600 0.082 775 736 34.32 * Other sections may be available upon request. ** Ambient Temperature: 60˚C. Maximum conductor Temperature: 120˚C Values are subject to manufacturing tolerances. SEA 01/2023


TECHNICAL INFORMATION SECTION 5 : SECTION 5 :


81


82


83


84


85


86


87


88


89


90


91


92


93


94


95


96


97


98


99