Openersclosers Catalogue 2018

Openersclosers Catalogue 2018

5F 5UF

Pure strength! Passionate about
Resistance within reach the details!
Compact and universal
Made entirely out of an extremely
resistant alloy that adapts to The design of our new universal
the geometric complexity of the coil offers the advantage of
electric strike. Every little detail unifying models and performing
has been passionately designed faster installations. Making
to improve its efficiency on fire this the most versatile electric
and high security doors. strike for fire solutions yet.

16 MM UP TO 9-24 V EI 90

DE ANCHO 200 N 22-28 V

50 SIDE - LOAD AC / DC
AC

Technical
characteristics

Break-in resistance 8.000 N
(keeper’s pressure)

Dynamic strength 4.400 N
(door impact)

Endurance rating C 200.000
(cycles with no side-load)

Fire resistant 90 min.

Temperature - 25 ºC to + 70 ºC 7,1 9,2

Complies with the directive:

2014/30/UE

19,5 16 2011/6159/,5UE16
Accredited with EN14846 certificate:

Fail-secure / Fail-safe: 3 C 3 E 0 H 0 0 0

Fail-secure / Fail-safe 3 C28 3 E 0 H 0 1 0 28
with micro:

0432-CPR-00406-01.1

7,4 9,2

21,2 16 17,4 19 21,2

28 28
31,4 31,4

OPENERS&CLOSERS
09/2018 EDITION

5EF ELECTRIC
STRIKES
The future is electronic!
Unique 5F
5UF
Our engineers at O&C found a sophisticated 5EF
and advanced solution for any fire door that
requires an extra layer of protection: to include
a microprocessor that unlocks the door from 6
to 28V AC / DC. While increasing the side-load
up to 400 N. This powerful chip is also respon-
sible for controlling the temperature of the
electronic strike so it doesn't exceed 40 °C.

New
Latch guide

INTERCHANGEABLE UP TO ELECTRONIC 6 - 28 V
MICRO SWITCH MICROCHIP
400 N AC / DC
The monitoring that
detects the status of SIDE - LOAD 100%
the door has now an AC - DC
interchangeable position
to provide a more
comfortable and secure
installation.

THE TOUGHEST
MATERIAL

Fully manufactured

in a steel alloy that

47,2 7,1 99,2,2 7,4 47,2 can withstand ah9nig,d2hhel7p,s4
temperatures

maintain fire doors sealed.

OPTIMAL REGULATION

An ingenious redesign of

52,3 52,3 the mechanism housing
65,6 has increased the depth
73
72,7 65,6 of the keeper to 6mm and
80,1
73 3mm adjustability while
47,1 maintaining its perfect

72,7 radial rotation.

80,1

7,4 99,2,2 7,4 47,1 9,2 7,4

16 17,4 19 52,3
65,5
52,3 72,9
65,5
72,9 72,9
72,9 80,3
80,3

51

NEW ITEM NUMBERS (EXAMPLE)

Model Function Coil Keeper Cover
5U 0X (K) (C)

ITEM NUMBERS AND FEATURES
Functions

5 y 5U 5E 5F y 5UF

0. Fail-secure Left Microswitch
upon request
1. Fail-secure
with mechanical
unlocking

2. Hold-open

3. Hold-open
with mechanical
unlocking

4. Fail-safe

6. Fail-secure
with monitoring

8. Fail-safe with
monitoring

52

OPENERS&CLOSERS
09/2018 EDITION

5EF Creating new item numbers ELECTRIC
STRIKES
Remember to replace the (K) and (C) that correspond to the Keeper and the Cover of the product by the desired number.
See the next page for an easy selection. For example:
5U0X(K)(C) would become 5U0X21 if we chose Keeper 2 and Cover 1.

5 5U 5E 5F 5UF 5EF

50B(K)(C) 5U0X(K)(C) 5E0Z(K)(C) 5F0B(K)(C) 5UF0X(K)(C) 5EF0Z(K)(C)
50D(K)(C) 5U0Y(K)(C) 5F0D(K)(C) 5UF0Y(K)(C)
50E(K)(C) 5F0E(K)(C)
50F(K)(C) 5F0F(K)(C)
50H(K)(C) 5F0H(K)(C)

5

51B(K)(C)

51D(K)(C) 5U1X(K)(C) 5E1Z(K)(C) - - -
51E(K)(C) 5U1Y(K)(C)
51F(K)(C)

51H(K)(C)

52B(K)(C)

Electronic 52D(K)(C) 5U2X(K)(C) 5E2Z(K)(C) - - -
52E(K)(C) 5U2Y(K)(C)
52F(K)(C)

Unique in the world 52H(K)(C)

Developed with cutting-

edge electronic components.

Ask our sales team for more 53B(K)(C)

information! 53D(K)(C) 5U3X(K)(C)
53E(K)(C) 5U3Y(K)(C)
53F(K)(C) 5E3Z(K)(C) - - -

53H(K)(C)

54E(K)(C) 5U4X(K)(C) 5E4Z(K)(C) - - -
54F(K)(C) 5U4Y(K)(C)

56B(K)(C) 5U6X(K)(C) 5E6Z(K)(C) 5F6B(K)(C) 5UF6X(K)(C) 5EF6Z(K)(C)
56D(K)(C) 5U6Y(K)(C) 5F6D(K)(C) 5UF6Y(K)(C)
56E(K)(C) 5F6E(K)(C)
56F(K)(C) 5F6F(K)(C)
56H(K)(C) 5F6H(K)(C)

58E(K)(C) 5U8X(K)(C) 5E8Z(K)(C) - - -
58F(K)(C) 5U8Y(K)(C)

53

Coils B D E F

Electrical characteristics 6-14V AC/DC 24V AC 12V DC 24V DC
Electrical data < 1 min < 1 min ED 100% ED 100%
Continuous duty Sí
Transient Voltage 8,5 Ω Sí Sí Sí
Suppressor (TVS) 42 Ω 42 Ω 200 Ω
Rated resistance 0,50 A ....... 6V 0,4 A
Current consumption 1 A .............. 12V - -
AC 1,16 A ....... 14V -
0,71 A ....... 6V 0,29 A 0,12 A
Current consumption 1,41 A ....... 12V 120 N
DC (stabilized) 1,65 A ....... 14V - - -
10 N 10 N
Maximum side-load 12V - 120 N 5 and 5F 5 and 5F 5 and 5F
on AC
Maximum side-load 12V - 10 N
on DC (stabilized)
5 and 5F
Compatible coils for:
Item numbers Adjustable keeper made of zamak for models:
Keeper (K) 5 / 5U / 5E
Remember to replace the Suitable for features: 0 / 1 / 4 / 6 / 8
(K) and (C) with a number. 1 X= 5,2 mm
Y= 7,1 to 9,1 mm
Ex .: 5U0X(K)(C) would be 14,2
5U0X21 if we choose Adjustable keeper made of zamak for models:
Keeper 2 and Cover 1. 5 / 5U / 5E
Suitable for features: 2 / 3
46,7 X= 5,2 mm
Y= 7,1 to 9,1 mm
2
Adjustable keeper made of zamak for models:
13 5 / 5U / 5E
Suitable for features: 0 / 1 / 4 / 6 / 8
1 X= 5,2 mm
Y= 7,1 to 9,1 mm
2 13
Adjustable keeper made of steel for models:
Cover (C) 5F / 5UF / 5EF
Suitable for features: 0 / 6
X= 6 mm
Y= 7,1 to 10,1 mm

Adjustable keeper made of steel for models:
5F / 5UF / 5EF
Suitable for features: 0 / 6
X= 6 mm
Y= 7,1 to 10,1 mm

0 Standard ¡NEW COVER!
Inox Latch guide

1 Latch Designed for installations in the center of the
guide door frame or to avoid cutting the frame.

Compatible with keeper's 2 and 7

54

H X Y Z OPENERS&CLOSERS
09/2018 EDITION
9-16V AC/DC 9-24V AC/DC 22-28V AC/DC 6-28V AC/DC ELECTRIC
< 1 min 12V DC 24V DC 5 STRIKES
Sí ED 100%
14 Ω < 1 min / ED 100% < 1 min / ED 100%

0,45 A ....... 9V Sí Sí
0,61 A ....... 12V 6,5 Ω
0,81 A ....... 16V 43 Ω 200 Ω
0,64 A ....... 9V Initial: Maintenance:
0,86 A ....... 12V 0,15 A ....... 9V 0,08 A ....... 22V
1,14 A ....... 16V 0,2 A .......... 12V 0,08 A ....... 24V 0,18 A ......... 6V 0,10 A ............. 6V
0,39 A ....... 24V 0,10 A ....... 28V 0,39 A ......... 12V 0,21 A ............. 12V
12V - 120 N 0,24 A ......... 24V 0,11 A ............. 24V
0,21 A ....... 9V 0,11 A ....... 22V
12V - 10 N 0,28 A ....... 12V 0,12 A ....... 24V Initial: Maintenance:
0,56 A ....... 24V 0,14 A ....... 28V
5 and 5F 0,16 A ......... 6V 0,09 A ............. 6V
24 V - 200 N 28 V - 200 N 0,34 A ......... 12V 0,14 A ............. 12V
0,17 A ......... 24V 0,07 A ............. 24V
12V - 50 N 24V - 50 N
12V 100% ED 24V 100% ED 6 - 28V - 400 N
6 - 28V - 400 N
5U and 5UF 5U and 5UF
5E and 5EF

3 Adjustable keeper made of zamak for models:
4 13 5 / 5U / 5E
5
6 Suitable for features: 0 / 1 / 4 / 6 / 8
7
8 X= 5,2 mm
Y= 5,6 to 7,6 mm
Latch
Adjustable keeper made of zamak for models:
17 5 / 5U / 5E

Suitable for features: 0 / 1 / 4 / 6 / 8

X= 4,2 mm
Y= 8,1 to 10,1 mm

Adjustable keeper made of zamak for models:
17 5 / 5U / 5E

Suitable for features: 0 / 1 / 4 / 6 / 8

X= 5,2 mm
Y= 7,1 to 9,1 mm

Adjustable keeper made of zamak for models: Keeper x
5 / 5U / 5E Section view

Suitable for features: 0 / 1 / 4 / 6 / 8

X= 4,2 mm
Y= 8,1 to 10,1 mm

Adjustable keeper made of zamak for models: y
13 5 / 5U / 5E

Suitable for features: 0 / 1 / 4 / 6 / 8

X= 4,2 mm
Y= 8,1 to 10,1 mm

Adjustable keeper made of zamak for models: Dimension X
5 / 5U / 5E Keeper depth
Dimension Y
Suitable for features: 0 / 1 / 4 / 6 / 8 Keeper’s adjustability from
min. to max.
X= 5,7 mm
Y= 5,6 to 7,6 mm

Door frame The latch guide cover allows the door latch to neatly
slide into position without blocking the door.
Guide cover
Common problem: when the door is about to be
Kepper opened, the door latch gets stuck between the
electric strike and the doorframe.

O&C solution: Thanks to the latch guide cover,
the door latch can’t get stuck in the cavity. The
latch will thus smoothly slide into position and
unlock the door.

SECTION VIEW

55

ELECTRIC STRIKES IP54*

SERIES 7 *IP54 protection
against dust and
WATERPROOF! pulverized water on an
average of 10 liters per
Enjoying the outdoors minute and pressure
of 80-100kN/m2.
Sometimes electric strikes are subjected
to sudden weather changes which may
affect their internal mechanism.

In order to isolate this internal mechanism
we have developed an external keeper
for the box and an independent electrical
connection, resulting in a waterproof
electric strike able to withstand heavy rain.

21 36 45,5 44,5 8,9

56 93,2
98,9

Technical OPENERS&CLOSERS ELECTRIC
characteristics 09/2018 EDITION STRIKES

Break-in resistance 3.500 N 7
(keeper’s pressure)

Endurance rating C 200.000
(cycles with no side-load)

Endurance rating W
(cycles with 120 N side-load AC ) 100.000

Temperature - 25 ºC to + 70 ºC

Complies with the directive:
2014/30/UE
2011/65/UE

According to EN 14846 standard

Fail-secure: 3W1 0 0 L 0 0 0

Fail-safe: 3C1 0 0 L 0 0 0
3W1 0 0 L 0 1 0
Fail-secure 3C1 0 0 L 0 1 0
with micro:
Fail-safe
with micro:

WATER TIGHTNESS TEST MAGNETIC MICROSWITCH GOOD FOR MULTPOINT
BOLT LOCKS
We have isolated the inside of the A hidden magnetic sensor allows
mechanism to prevent corrosion. us to know the status of the door The design of the mechanism
The electric strike has been and keep water and dust away box is curved so the end
certified with the IP54 protection from the internal mechanism. matches the first bolt lock.
against dust and water.

57

NEW ITEM NUMBERS (EXAMPLE)

Model Function Coil Keeper Cover
7R 0L 4 0

ITEM NUMBERS AND FEATURES 7 DIN R 7 DIN L
Functions

0. Fail-secure 7R0D40 7L0D40
7R0L40 7L0L40
7R0M40 7L0M40
7R0N40 7L0N40
7R0P40 7L0P40

Important

Install the electric
strike so that the
coil is positioned
at the top.

4. Fail-safe 7R4M40 7L4M40
7R4N40 7L4N40
7R4P40 7L4P40

6. Fail-secure 7R6D40 7L6D40
with monitoring 7R6L40 7L6L40
7R6M40 7L6M40
7R6N40 7L6N40
7R6P40 7L6P40

8. Fail-safe with 7R8M40 7L8M40
monitoring 7R8N40 7L8N40
7R8P40 7L8P40

A. Internal 7RAD40 7LAD40
hold-open 7RAL40 7LAL40
7RAP40 7LAP40
58

OPENERS&CLOSERS
09/2018 EDITION

Coils D L M N P ELECTRIC
STRIKES
Electrical characteristics 24V AC 8-14V AC/DC 12V DC 24V DC 12V DC
< 1 min ED 100% ED 100% ED 100% 7
Electrical data < 1 min
- - Sí Sí Sí
Continuous duty 70 Ω 70 Ω 240 Ω 54 Ω
Transient Voltage 0,24 A 20 Ω
Suppressor (TVS) 0,28 A ....... 8V 0,17 A - -
Rated resistance - 0,42 A ....... 12V
0,49 A ....... 14V - 0,1 A 0,22 A
Current consumption 120 N 0,4 A .......... 8V 10 N
AC - 0,6 A .......... 12V - -
0,7 A .......... 14V 10 N 10 N
Current consumption
DC (stabilized) 12V - 120 N

Maximum side-load 12V - 10 N
on AC

Maximum side-load
on DC (stabilized)

Keeper section view Dimension X
Keeper depth
Our special Keepers and Covers 15,7 Dimension Y
ensures the best fitting possible Keeper’s adjustability
44,3 from minimum
Keeper to maximum
Section view
4
Fixed keeper
Cover made of zamak
X= 8,8 mm
Y=12,8 mm

0 Nylon

Reed Contact CHARACTERISTICS
• Maximum switching
The Reed is a sensor that detects and Reed
monitors the door’s position. voltage: 100 V DC
The microswitch activates magnetically, • Maximum switching
thus avoiding the need to perforate the
box. Watertightness assured! current: 300 mA DC
• Maximum power
SECTION VIEW
load: 3 W

59

ELECTRIC STRIKES

SERIES 9

ARMOURED

High security at
your fingertips

An electric strike developed for
armoured doors with multipoint bolt
locks. We want to ease accessibility
of heavy doors with robust locks.

Technical characteristics

Break-in resistance 4.000 N
(keeper’s pressure)

Endurance rating C 200.000
(cycles with no side-load)

Endurance rating X
(cycles with 120 N side-load AC) 200.000

Temperature - 25 ºC to + 70 ºC

Complies with the directive:
2014/30/UE
2011/65/UE

According to EN 14846 standard

Fail-secure: 3X300L000

Fail-safe: 3C3 0 0 L 0 0 0

23 43,7 36,3 9
32
83,3
60 88,8

OPENERS&CLOSERS ELECTRIC
09/2018 EDITION STRIKES

9

COMPACT AND SMALL INFALLIBLE DESIGNED FOR
MULTIPOINT LOCKS
The latch’s size has been reduced to The new design of the hold-open
make it more adaptable and for the system ensures that the door latch is The end of the box is curved so
fastener to gain more resistance. always in contact with it, even if the the separation between lock
keeper moves to adjust to the door. and the first bolt is only 5 mm.

61

NEW ITEM NUMBERS (EXAMPLE)

Model Function Coil Keeper Cover
9R 0L (K) 0

ITEM NUMBERS AND FEATURES 9 DIN R 9 DIN L
Functions

0. Fail-secure 9R0D(K)0 9L0D(K)0
9R0L(K)0 9L0L(K)0
9R0M(K)0 9L0M(K)0
9R0N(K)0 9L0N(K)0
9R0P(K)0 9L0P(K)0

9R2D(K)0 9L2D(K)0 Important
9R2L(K)0 9L2L(K)0
9R2M(K)0 9L2M(K)0 Install the electric
9R2N(K)0 9L2N(K)0 strike so that the
9R2P(K)0 9L2P(K)0 coil is positioned
at the top.

2. Hold-open

3. Hold-open 9R3D(K)0 9L3D(K)0
with mechanical 9R3L(K)0 9L3L(K)0
unlocking 9R3M(K)0 9L3M(K)0
9R3N(K)0 9L3N(K)0
9R3P(K)0 9L3P(K)0

4. Fail-safe 9R4M(K)0 9L4M(K)0
9R4N(K)0 9L4N(K)0
9R4P(K)0 9L4P(K)0

A. Internal hold-open 9RAD(K)0 9LAD(K)0
9RAL(K)0 9LAL(K)0
9RAP(K)0 9LAP(K)0

B. Internal hold-open 9RBD(K)0 9LBD(K)0
with mechanical 9RBL(K)0 9LBL(K)0
unlocking 9RBP(K)0 9LBP(K)0

62

OPENERS&CLOSERS
09/2018 EDITION

Coils D L M N P ELECTRIC
STRIKES
Electrical characteristics 24V AC 8-14V AC/DC 12V DC 24V DC 12V DC
< 1 min ED 100% ED 100% ED 100% 9
Electrical data < 1 min
- - Sí Sí Sí
Continuous duty 70 Ω 70 Ω 240 Ω 54 Ω
Transient Voltage 0,24 A 20 Ω
Suppressor (TVS) 0,28 A ....... 8V 0,17 A - -
Rated resistance - 0,42 A ....... 12V
0,49 A ....... 14V - 0,1 A 0,22 A
Current consumption 120 N 0,4 A .......... 8V 10 N
AC - 0,6 A .......... 12V - -
0,7 A .......... 14V 10 N 10 N
Current consumption
DC (stabilized) 12V - 120 N

Maximum side-load 12V - 10 N
on AC

Maximum side-load
on DC (stabilized)

Keeper section view Dimension X
Keeper depth
Creating new item numbers Dimension Y
Keeper’s adjustability
Remember to replace the (K) that correspond to the Keeper of the product from minimum
by the desired number. For example: to maximum
Section view
9R0L(K)0 would be 9R0L20 if we chose Keeper 2.
Adjustable keeper
Keeper (K) 14,2 made of zamak.
Suitable for all
1 34,8 functions. Features
2 / 3 manufactured
2 with a hole.
X= 6 mm

Adjustable keeper
made of zamak.
Suitable for all
functions. Features
2 / 3 manufactured
with a hole.
X= 9,3 mm

Cover

0 SST

63

ELECTRIC STRIKES

SERIES 25

SMALL AND INCREDIBLE!

100% Reversible

Entirely made of special steel alloy
increases the resistance of the
electric strike to 8.000 N.
A symmetric construction with radial
adjustable keeper and electronic protection
that provide versatility to your installation.

25

64

OPENERS&CLOSERS ELECTRIC
09/2018 EDITION STRIKES

25

25E

65

25 Technical characteristics

Maximum resistance Break-in resistance 8.000 N
Ideal for heavy and (keeper’s pressure)
high-security doors!
Dynamic strength 4.450 N
A larger span of the electric strike (door impact)
ensures instant blocking of heavier doors.
The huge selection of voltages allows a Endurance rating C 200.000
quickly aperture with only one function (cycles with no side-load)
of the energy consume. The series 25
has the highest side-load of all models. Temperature - 25 ºC to + 70 ºC

66 Complies with the directive:
2014/30/UE and 2011/65/UE

Technical characteristics 25

Endurance rating X 200.000
(cycles with 120 N side-load on AC)

Complies with EN14846:

Fail-secure: 3X300L000

Fail-safe: 3C3 0 0 L 0 0 0

Fail-secure 3X300L010
with micro: 3C3 0 0 L 0 1 0
Fail-safe
with micro:

Technical characteristics 25E

Endurance rating Y
(cycles with 250 N side-load on AC/DC) 200.000

Complies with EN14846:

Fail-secure: 3Y300L000

Fail-safe: 3C3 0 0 L 0 0 0
3Y300L010
Fail-secure 3C3 0 0 L 0 1 0
with micro:
Fail-safe 8,4 12,75
with micro:

20,5 20,5
28 28

OPENERS&CLOSERS
09/2018 EDITION

25E ELECTRIC
STRIKES
Smart management
Electronics makes us universal

An electronic microchip is responsible for automatically
managing any voltage from 6 - 28 V AC/DC 100%. It also
incorporates a temperature detection system to prevent
the mechanism from overheating reaching maximum
temperatures of 40ºC. The internal programming
achieves a greater capacity of lateral preload increasing it
up to 400 N.

UP TO 6 - 28 V 25
25E
400 N AC / DC
ELECTRONIC
SIDE - LOAD MICROCHIP 100%
AC - DC

CURVES ARE BEAUTIFUL

The radial keeper turns
inside the mechanisms box,
which means you won’t
need to cut the doorframe.

DEEP AND ADJUSTABLE
For a better adjustment, the
depth has been increased up
to 6 mm for the adjustable
keeper, with a displacement
of 3 mm for an accurate
adjustment for the door.

AUTOMATIC SYSTEM
The joint of the keeper
and the automatic switch
removes the critical spaces
and offers a better contact
with the latch of the door.

44,5 8,4 12,75 12,75 7,3 44,5 12,75 7,3

52,3 52,3
70 70
78,5 78,5
85,7 85,7

67

NEW ITEM NUMBERS (EXAMPLE)

Model Function Coil Keeper Cover
25E 0Z 1 0

ITEM NUMBERS AND FEATURES

Functions 25 25E
25E0Z10
0. Fail-secure 25E2Z10
25E4Z10
250B10 25E6Z10
250D10 25E8Z10
250E10
250F10
250H10
250S10

2. Hold-open

252B10
252D10
252E10
252F10
252H10
252S10

4. Fail-safe

254E10
254F10

6. Fail-secure 256B10
with monitoring 256D10
256E10
8. Fail-safe with 256F10
monitoring 256H10
256S10

258E10
258F10

68

OPENERS&CLOSERS
09/2018 EDITION

Coils B D E FHS Z

Electrical characteristics 6-14V AC/DC 24V AC 12V DC 24V DC 8-14V AC/DC 8V DC 6-28V AC/DC ELECTRIC
< 1 min ED 100% ED 100% ED 100% STRIKES
Electrical data < 1 min < 1 min ED 100%
- - Sí Sí Sí
Continuous duty 50 Ω 50 Ω 185 Ω - 25 Ω Sí
Transient Voltage 8,5 Ω 0,34 A
Suppressor (TVS) 0,5 A .......... 6V - - 14 Ω - 6,5 Ω
Rated resistance 1 A .............. 12V -
1,16 A ....... 14V 0,24 A 0,13 A 0,4 A .......... 8V 0,32 A Initial: Maintenance:
Current consumption 0,71 A ....... 6V 120 N 0,61 A ....... 12V
AC 1,4 A .......... 12V - - 0,71 A ....... 14V 0,18 A ... 6V 0,10 A ... 6V
1,65 A ....... 14V 10 N 0,39 A ... 12V 0,21 A ... 12V
Current consumption 25 0,57 A ....... 8V 0,24 A ... 24V 0,11 A ... 24V
DC (stabilized) 12V - 200 N 0,86 A ....... 12V
1 A .............. 14V Initial: Maintenance:
Maximum side-load 12V - 10 N
on AC 0,16 A ... 6V 0,09 A ... 6V
0,34 A ... 12V 0,14 A ... 12V
Maximum side-load 0,17 A ... 24V 0,07 A ... 24V
on DC (stabilized)
- 120 N - 6 - 28V - 400 N 25
25E

10 N 10 N 10 N 6 - 28V - 400 N

Compatible coils for: 25 25 25 25 25 25E

Keeper section view x
Dimension X
Our special Keepers and Covers Keeper depth
ensures the best fitting possible
y Dimension Y
Keeper’s adjustability from
minimum to maximum

Section view

Keeper

1

15 Adjustable keeper made of zamak
43,8 Suitable for functions 0 / 4 / 6 / 8
With lever suitable for function 2

X= 6 mm
Y = 7 a 10 mm

Cover

0 SST

69

70

OPENERS&CLOSERS
09/2018 EDITION

FACEPLATES

Faceplates fasten, embellish, protect electric doors and strikes.
Our selection of faceplates adds a touch of design, allowing you to choose
from a wide range of shapes and colors.

71

FACEPLATES

PERSONALIZE

We can create different shapes or hole positions to personalize your ideal faceplate.
Contact us and we will advise you to choose the one that best suits your needs.

LASER

We can laser print your logo on the faceplate. For this option add the letter L after the
color category. If you wish the logo to be on both sides add the letter R.

72

OPENERS&CLOSERS
09/2018 EDITION

Easy coding! Additional given information

+ Brown
Inox
Grey
Black
White
Special colors
(choose RAL)
No laser print
One side
Two side.
Reversible

FACEPLATES
Model Color + Laser print DIN 107 Recommended series

Usual colors

BOX B09 B X Z KW S - LR DIN R 2S 3 4 5 7 9 25 Reference
FACEPLATE B10 DIN L 2S 3 4 5 7 9 25 example:
B11 B X Z KW S --- DIN R 2S 3 4 5 7 9 25 Model +
SHORT B12 B X Z KW S --- DIN L 2S 3 4 5 7 9 25 Color +
FACEPLATE B81 B X Z KW S --- REVERSIBLE 2 3 4 5 7 9 25 Laser (optional)
B84 B X Z KW S --- REVERSIBLE 2 3 4 5 7 9 25
ANGLED B86 B X Z KW S - LR REVERSIBLE 2 3 4A 5 7 9 25 L03X
FACEPLATE B87 B X Z KW S - LR REVERSIBLE 2 3 4A 5 7 9 25 LC3ZL
S01 B X G KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LONG S02 B X G KW S - LR REVERSIBLE 2 3 4 5 7 9 25
FACEPLATE S27 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
S28 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
Standard holes S66 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L03 S76 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L04 S80 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L05 S92 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L43 S94 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
Centered holes S95 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LC3 S96 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LC4 A08 B X Z KW S - LR DIN R 2 3 4 5 7 9 25
LC5 A09 B X Z KW S - LR DIN L 2 3 4 5 7 9 25
LC43 A10 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
Diagonal holes A11 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
LD3 A12 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
LD4 A13 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
LD5 A14 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
LD43 A15 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
A16 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
A17 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
A24 B X Z KW S - LR DIN R 2 3 4 5 7 9 25
A25 B X Z KW S - LR DIN L 2 3 4 5 7 9 25
A44 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
A45 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
A47 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
A48 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
A49 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
A50 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
L03 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
LC3 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
LD3 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L04 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LC4 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LD4 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L05 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LC5 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LD5 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L20 B X Z KW S - LR DIN R 2 3 4 5 7 9 25
L21 B X Z KW S - LR DIN L 2 3 4 5 7 9 25
L22 B X Z KW S -L- DIN R 2 3 4 5 7 9 25
L23 B X Z KW S -L- DIN L 2 3 4 5 7 9 25
L26 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
L29 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
L30 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L38 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L39 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L43 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LC43 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
LD43 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L60 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L67 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L68 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L69 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L70 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L71 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L72 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L73 B X Z KW S - LR DIN R 2 3 4 5 7 9 25
L74 B X Z KW S - LR DIN L 2 3 4 5 7 9 25
L75 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
L79 B X Z KW S -L- REVERSIBLE 2 3 4 5 7 9 25
L94 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L95 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
L96 B X Z KW S - LR REVERSIBLE 2 3 4 5 7 9 25
B X Z KW S - LR
B X Z KW S - LR

73

BOX

DIN R DIN L
B09K B10K
B09S B10S

Rev. DIN R DIN L
B81B B11K B12K
B81Z B11S B12S
B81K
B81W
B81S

Thickness Rev. Rev. Rev.
C86 B84B B86X B87X
6 units B84Z B86G B87G
included B84K B86K B87K
Antivandalic B84W B86W B87W
base B84S B86S B87S

For more information
consult Series 4

74

OPENERS&CLOSERS
09/2018 EDITION

SHORT FACEPLATES

BOX AND SHORT

Rev. Rev. Rev. Rev.
S01B S02B S27X S28X
S01X S02X
S01Z S02Z
S01K S02K
S01W S02W
S01S S02S

Rev. Rev. Rev. Rev.
S66X S76X S80B S92X
S80Z
S80K
S80W
S80S

Rev. Rev. Rev. B. Brown
S94X S95X S96X X. Inox
Z. Grey
K. Black
W. White
S. Special color

75

ANGLED

DIN R DIN L
A08B A09B
A08Z A09Z
A08K A09K
A08W A09W
A08S A09S

DIN R DIN L
A14B A15B
A14Z A15Z
A14K A15K
A14W A15W
A14S A15S

B. Brown DIN R DIN L
X. Inox A44B A47B
Z. Grey A44Z A47Z
K. Black A44K A47K
W. White A44W A47W
S. Special color A44S A47S

76

OPENERS&CLOSERS
09/2018 EDITION

FACEPLATES

ANGLED

DIN R DIN L DIN R DIN L
A10B A11B A12B A13B
A10Z A11Z A12Z A13Z
A10K A11K A12K A13K
A10W A11W A12W A13W
A10S A11S A12S A13S

Rev. Rev. DIN R DIN L
A16B A17B A24X A25X
A16Z A17Z
A16K A17K
A16W A17W
A16S A17S

DIN R DIN L DIN R DIN L
A45B A48B A49X A50X
A45Z A48Z
A45K A48K 77
A45W A48W
A45S A48S

LONG Rev. Rev. Rev.
L03B L04B L05B
B. Brown L03X L04X L05X
X. Inox L03Z L04Z L05Z
Z. Grey L03K L04K L05K
K. Black L03W L04W L05W
W. White L03S L04S L05S
S. Special color

Standard

L03
L04
L05
L43

Centered

LC3
LC4
LC5
LC43

Diagonal

LD3
LD4
LD5
LD43

Rev. Rev. Rev. Rev.
L29X L30X L38X L39X

Rev. Rev. Rev. DIN R
L70X L71X L72X L73X

78

OPENERS&CLOSERS
09/2018 EDITION

FACEPLATES

LONG

DIN R DIN L DIN R DIN L Rev.
L20X L21X L22X L23X L26X

Rev. Rev. Rev. Rev. Rev.
L43X L60X L67X L68X L69X

DIN L Rev. Rev. Rev. Rev. Rev.
L74X L75X L79X L94X L95X L96X

79

DUMMIES

Don’t be a dummy, protect your installation
Mechanical electric strike

Dummies are often used during construction work for building safety. They are used
to keep doors closed or grant easy access to areas that are under construction. This
will avoid valuable electric strikes deterioration or theft of materials.

SERIES 3 SERIES 5
D30010 D50021

Always open Always open

SERIES 5 SERIES 25
D50010 D250010

Always open Always open

CSR001

Always closed

PERSONALIZE SERIES 3 SERIES 5 SERIES 25
D250010
We can customize the mechanical models by D30010 D50010
choosing the Keeper (K) and the Cover (C) that D300(K)(C) D500(K)(C)
suits you best. Consult the page of the ITEM
NUMBERS AND FEATURES of each series.

80

OPENERS&CLOSERS
09/2018 EDITION

COMPLEMENTS COMPLEMENTS

BLACK BOX

The importance of the details
Groove embellisher

A black box is an elegant solution to limit the holding
place of the bolts. It goes installed behind the faceplate
hiding the ugly insides of the door leaf from sight.

HL
Long box

HS
Short box

17,5 26

18,9 26

101,65 80,15

1,5
1,5

81

82

OPENERS&CLOSERS
09/2018 EDITION

ELECTROMAGNETIC LOCKS

Electromagnetic locks or maglocks consist of a powerful
electromagnet mounted on the door frame and a counterplate
mounted on the door. Once activated the electromagnet holds fast
to the counterplate and the door remains closed. Two LED’s informs
at a glance whether the electromagnetic lock is open or closed.
Maglocks are popular among our customers for its effortless
installation, durability and trustworthiness. At O&C we
offer a vast range of maglocks in different sizes, voltages,
mountings and holding forces to best suit your needs.

83

INSTALLATION OF AN ELECTROMAGNETIC LOCK

L

L installation
For doors that
open outwards.

The counterplate is fixed
directly on the door leaf
and the electromagnet
installed on the lintel. If
the frame is too small we
use an L-shaped bracket.
ME and MEX

U

U installation
For glass doors

In order to prevent damage
to your glass door the
counterplate has to be
installed using a U-shaped
bracket which is fastened
to the top of the door leaf.
ME and MEX

S S installation
For sliding doors
84
The electromagnet is
imbedded into the side of
the doorframe, while the
counterplate goes fixed
to the side of the door
using a small and discrete
U-shaped support.

ME

OPENERS&CLOSERS ELECTROMAGNETIC
09/2018 EDITION LOCKS

Z installation Z
For doors that
open inwards. F

A Z-shaped bracket is used E
to attach the counterplate
to the door leaf. 85

ME and MEX

A magnetic contact is F installation
required to detect that For fire doors
the door is aligned and
then powered (You can The counterplate is
check the SERIES CM). connected to a specific
support for Ei doors. In this
way, it is not necessary to
completely perforate the
door and lose its certification.

ME and MEX

New!

E installation
Embedded
installation

The new invisible installation
offers architects and
engineers a great solution
to aesthetic and safety
problems. The electromagnet
and the counterplate are
embedded in the frame and
the door leaf respectively.
Ideal for swinging or
door-only doors.

ME

SERIES ME 30 mm

SLIM AND STRONG

An elegant solution

We have developed the thinnest electromagnetic lock
on the market. With only 30mm width it fits on the most
sophisticated of your interior decoration without
losing holding force.

Not only is the Series ME the smallest, it’s also the most
sensible to unwanted intruders, being able to detect the
smallest tampering attempts.

We like details, for this reason, each unit comes certified
with its real closing force and we have accomplished the
lowest magnetic remanence.

ME500/510
WATERPROOF IP65

2.500 N Holding force

ME400/420/440
2.800 N Holding force

Power
AC/DC

ME440: the smart one. The maglock has been fitted with an electric NC
circuit that allows it to activate a timer. Also this electromagnetic lock NO
has an automatic voltage detection system on a broader voltage span COM
(9-24V AC/DC).
Delay
86 1s / 20s

ME440 New
12V DC 400mA

OPENERS&CLOSERS ELECTROMAGNETIC
09/2018 EDITION LOCKS

ME

ME600/620
2 .800 N Holding force

ME200/210 Counterplate mounting kit
2.800 N Holding force included L and Z installation
For wood installation
87
ME201/211
2.800 N Holding force
For metal installation

Holding force
Manual voltage change
12 / 24 V DC
Automatic voltage change
9 - 24 V AC/DC
Embedded
Surface
Door Status (Reed)
LED
Timer:
1 to 20 s (6 by default)

202 26 ME200 2.800 N Yes - Yes - - - -

249 35
12
30
185
6W / 1,55 kg
12 V DC (500 mA) 24 V DC (250 mA) ME210 2.800 N Yes - Yes - Yes - -

26 ME201 2.800 N Yes - Yes - - - -
202

239

30

ME211 2.800 N Yes - Yes - Yes - -
-
6W / 1,55 kg -
12 V DC (500 mA) 24 V DC (250 mA)

ME400 265 31 ME400 2.800 N Yes - - Yes - -
ME420 35

40 270 31,5
202 35

46 ME420 2.800 N Yes - - Yes Yes

ME440 202

6W / 1,74 kg ME440 2.800 N - Yes - Yes Yes 6s
12 V DC (500 mA) 24 V DC (250 mA)
12V DC (400mA)

31,5

228 1.100 a 1.200 mm ME500 2.500 N Yes - - Yes - - -

30 10 Opcional
2.000 mm
202
ME510 2.500 N Yes - - Yes Yes - -
IP65

Waterproof
6W / 1,78 kg
12 V DC (500 mA) 24 V DC (250 mA)

31 ME600 2.800 N Yes - - Yes - - -

525 35 x2

ME620 2.800 N Yes - - Yes Yes -
x2
6W / 3,48 kg
12 V DC (500 mA x 2) 24 V DC (250 mA x 2)

88

EMBELLISHER OPENERS&CLOSERS
for counterplates 09/2018 EDITION

Aluminium sticker to cover holes U F S E ELECTROMAGNETIC
FSC 821 for L (1 u.) LOCKS
FSC 822 for Z (2 u.) Glass doors Fire doors Sliding doors Embedded doors
Not valid for - MES1
MEE1
L Zwaterproof model - 38 26
25
Outward opening doors Inward opening doors

--- 50 189 212
ME

22

--- MES1 MEE1

38 26 25
50
189 212

MEL1 MEZ1 MEU1 MF1 22

265 -
-
220 26 8 -
35
50 50 270 190
50 39
Choose: 50 -
MEL1 or MEL2 50 -

270

50 MEZ1

50 MEL2 (for ME440)
MEL1

265

220

50 Select both: 50 50 -
50 MEL1 and MEL4 50
-
30 265
35
MEL4
MEL3 MEZ1 x2 MEU1 x2 MF1 x2

525 50 *

* * *Remember to

order 2 units

89

SERIES MEX

MAXIMUM RESISTANCE

High power and low consumption

To satisfy all your needs, we have created a maglock that uses the
least amount of power possible without losing any holding force.
It comes with an integrated timer, and most models come with a
standardized automatic voltage detection system (12-24V AC/DC)
Our vandal protection secures your maglock against external
tampering. This ensures that the lock cannot be manipulated,
removed or stolen.

MEX500/530
5.000 N Holding force

MEX400/430
2.800 N Holding force

MEX70
500 N Holding force

90

OPENERS&CLOSERS ELECTROMAGNETIC
09/2018 EDITION LOCKS

MEX

Our smallest and our strongest MEX600/630
2.800 N x2 Holding force
Tiny MEX70 has been specially
designed to keep your closets, drawers MEX100
and showcases properly locked. 1.800 N Holding force

91

Holding force
12 V DC
Multivoltage · Manual
12 / 24 V DC

Multivoltage · Automatic

12 - 24 V DC
Door status (Reed)
LED
Timer: 5, 10, 20 o 30 s
(5 by default)

90 31 MEX70 500 N - Yes - Yes - -
9,6
39,5
74
24

3,3 W / 0,5 Kg
12 V DC (300 mA) 24 V DC (150 mA)

166

40 31,5 MEX100 1.800 N Yes - - - - -
20 8,6

135,5

3 W / 1,2 Kg
12 V DC (250 mA)

241 MEX400 2.800 N - - Yes - - -

52 45,3 MEX430 2.800 N - - Yes Yes 5s
24 12,6

3,3 W / 2,25 Kg 156
12 V DC (270 mA) 24 V DC (180 mA)

MEX600 2.800 N - - Yes - - -
x2 -
482 - Yes Yes 5s
45,3
52 12,6
24
156
3,3 W / 4,4 Kg
12 V DC (270 mA x2) 24 V DC (180 mA x2) MEX630 2.800 N
x2

265

MEX500 5.000 N - - Yes - - -

70 62
35 13,6

173 MEX530 5.000 N -

- Yes Yes 5s

3,3 W / 4,1 Kg
12 V DC (270 mA) 24 V DC (180 mA)

92

OPENERS&CLOSERS
09/2018 EDITION

L Z U F ELECTROMAGNETIC
LOCKS
Outward opening doors Inward opening doors Glass doors Fire Doors

- MEXZ1 MEXU1 -

75 70 16
38
41
38 28

38

MEX

MEXL1 MEXZ2 MEXU2

166 136 136 27 135 30,5
35 40
45
40 45 30,5 -

45

MEXL2 MEXZ3 MEXU3 MF1

240 160 241 34 160 30,5
35 53 35
45 57 30,5 190 8
50

50

MEXL2 x2 MEXZ3 x2 MEXU3 x2 MF1 x2 *Remember to
* order 2 units

*

**

MEXL3 MEXZ4 MF1

266 180 241 34 190 8
53 35
40 75
75 70 - 93

70

SERIES DH

DOOR HOLDER

Fire Protection for the
most vulnerable

Door holders are used on swinging self-closing doors.
These can be found in hospitals, schools, nursing
homes as well as other public buldings and are used to
automatically isolate an area in case of fire. Since these
are very sensitive places, a reliable door holder is key.

These doors are heavy fire-blocking doors that are
kept open and closed only during emergencies. To
add an extra layer of safety magnetic door holders
have a holding force of 600 N and a manual red switch
which allows for instant closing of the doors.

60 28 15
60 50 Ø 55 Ø

24,7 55 Ø DHS 600 N
24 V DC
50 Ø 7 Basic
85 mA
DHI 600 N Holding force:
24 V DC
Industrial Voltage:
Holding force: 85 mA
Voltage: Consumption:
Consumption:

Accessories & Spares

AHI counterplate for DHI AHS counterplate for DHS PDH manual release button

94

OPENERS&CLOSERS
09/2018 EDITION

FIRE ELECTROMAGNETIC
LOCKS

Accredited with EN 1155: 1997 certificate 3 5 3 1 1 3
4

0370-CPR-1178 DH

47,3

83 50 Ø 65
90 65
55 Ø

Mobile
counterplate

51

Antiremanence
ejector

DHT DHB DHD

With timer Dual voltage With power-regulation

Holding force: 600 N Holding force: 600 N Holding force: 300 N | 600 N
24 V DC 12 V DC | 24 V DC
Voltage: Voltage: Voltage: 24 V DC
85 mA 170 mA | 85 mA
Consumption: 3s Consumption: Dual voltage Consumption: 85 mA

Timer: With jumper for

2 Jumpers. 12 V DC 1 Jumper. 24 V DC

83

83 80 83
80 83 300
90 339
200 160
247,3 386,3 90

80 FIX
SUPPORT
Floor - DF1 - Wall
ADH for DHB DHT DHD 80 Floor - DF2 - Wall

95

SERIES SH Technical features

SHEARLOCK Holding force: 15.000 N

Sleek and mighty SIGNAL Power from 10 to 36 V DC
(automatic switch)
In this day and age where minimalism is so in vogue, it is lights
pretty usual to have glass swinging and sliding doors even in Consumption at 12 V DC:
the most sensitive of work environments. ELECTRO 2A (start up) and 0,5A (operating)

Shearlocks are excellent for this kind of doors because they magnetic Timer:
combine magnetic and mechanical forces to create a holding Adjustable from 0 to 25 seconds for
force five times higher than your average maglock, reaching both locking (T1) and unlocking (T2)
up to 15.000N! This makes the Series SH a perfect candidate
to work as a sort of independent access control system, all on Operating temperature:
its own. from -14 to +40 ºC

Shearlocks can be easily hooked to heat and smoke detectors Auxiliary relay: 1A a 24 V DC maximum
as well as various access control systems and keypads. We have
also included a timer for both locking and unlocking which is ideal
for clearance through keypads or electronic readers that are not
situated next to your shearlock protected door.

Most electromagnetic locks come with two LEDs that inform
whether the door is closed or open. For your convenience,
we have added a third LED to report malfunction. This way
you will be able to detect when your shearlock is not properly
engaged at a glance.

3 mm 38 220
Maximum distance 38
between parts SH100
38 Surface
6,5 a 14 mm installation

Minimum distance between 60,5
glass: 6.5 mm
Maximum thickness of the glass: 14 mm

220

220

38 SH300 38
38 Glass / glass installation 38

46,50 60,5
96

OPENERS&CLOSERS
09/2018 EDITION

T1 T2 LED a. Locking-relay adjustment ELECTROMAGNETIC
b. Release-relay adjustment LOCKS
c. LED: opened, malfunction, closed

SH

The counterplate is installed on the
top of the door leaf with a U-shaped
bracket. The electromagnet is
then fixed to the frame’s lintel.

266 35

34 30
34
144 SH200
92 Embedded
installation

38 34 266
38 35
SH400
Surface / glass installation 60,5 220 SH500
Embedded / glass
installation

97

98

OPENERS&CLOSERS
09/2018 EDITION

ELECTRIC LOCKS

The electric lock is a locking device which is operated by an electrical
current and is usually connected to an access control system. It is
unlocked through a physical object (key, card, fingerprint, etc.), secret
code (key or password) or a combination of both. This allows for
greater security of access and control of your activity.

99