06 EAST ELEVATION CONCLUSION
MATERIAL SELECTION The stimulated results for the optimal proposed facade design on the selected
space has shown a significant reduction in terms of its average daylight factor
MATERIAL SELECTION and reduction of the area that gets exposed to high amount of daylight that will
caused glare and high heat trapped. Besides, the average illuminance has been
reduced and maintained at acceptable internal illuminance range as stated in
MS 1525 for more than 1/2 of the room. The width (thickness) of the facade also
has the impact in resulting in the coverage of the direct sunlight as the
travelling route for light is lengthen hence resulting in less coverage of direct
into the interior space. Besides, the size of the perforated also determines the
amount of sunlight passing through at one time, which bigger gap allows more
sunlight to pass through.
07 FIRE FIGHTING PRINCIPLES MEANS OF ESCAPE
FIRE APPLIANCE ACCESS & MEANS OF ESCAPE
FIRE APPLIANCE ACCESS
By-law Clause 140: Fire appliance access. The escape route and distance of this proposed Tourism and Hospitality
All buildings in excess of 7000 cubic metres shall abut upon a street or road or Vocational College in Kampong Bharu is based on UBBL Seventh Schedule
open space of not less than 12 metres width and accessible to fire brigade under purpose group II. Institutional, IV. Office, V. Shop and VII. Place of
appliances. The proportion of the building abutting the street, road or open Assemble. Although the building does not require a sprinkler which enabled the
space shall be in accordance with the following scale: furthest running distance to escape the configuration of the setting of the space
does comply with ‘dead-end limit’ and ‘2 or more alternative exit (un-sprinkled)’
to the nearest fire staircase.
Total in cubic metres: 36,300 cubic metres FIRE HYDRANT LOCATION
Total building perimeter: 425m / 4 = 107m
Therefore, the proposed building with a total volume of 36,300 cubic metres The site has two existing fire hydrants that cover almost all the proposed site.
falls under the category for minimum proportions of the perimeter of building With that, an additional fire hydrant is proposed around the site fulfil the
with one-fourth. The perimeter measured is 425m. Based on the calculation of requirement and coverage of the Tourism and Hospitality Vocational College
one-fourth (1/4), a total of 107. Perimeter access will be required for the fire building. Each of the hydrant suits the building by strategically located at the
appliance. frontage, back and side of the building near to both access to the building. Blue
colour indication is the existing and red in colour is the new proposed fire
hydrant to the side. New proposed college are within the radius coverage of
both fire hydrant.
07 FIRE FIGHTING PRINCIPLES MEANS OF ESCAPE
FIRE HYDRANT LOCATION & MEANS OF ESCAPE
FIRE HYDRANT LOCATION AND BOMBA ACCESS
07 FIRE FIGHTING PRINCIPLES FIRE EVACUATION
FIRE STAIRCASE AND BOMBA LIFT & FIRE EVACUATION
FIRE STAIRCASE AND BOMBA LIFT
07 FIRE FIGHTING PRINCIPLES
PASSIVE CLIMATE DESIGN
07 FIRE FIGHTING PRINCIPLES
RAINWATER HARVESTING AND WATER SUPPLY SYSTEM
RAINWATER HARVESTING SYSTEM
WATER SUPPLY SYSTEM
08 REFERENCES
Batavia River Street. Altamanu. (n.d.). http://www.altamanu.com/featured/batavia-river-street.
Bharu, K. (2017). Published online: 29 December 2017: Halimaton Saadiah Hashim, Sarah Aziz and Nik Mohd Ruiz Razy. 2017. Urban revitalisation for a city’s soul: The
case of Kampong Bharu. 35, 119–140.
Gehl, J. (2010). The City at Eye Level. In Cities for people. essay, Island Press.
Gehl, J. (2011). Life between buildings: using public space. Island Press.
PAUSE For Placemaking. The Architect's Newspaper. (2014, March 31). https://www.archpaper.com/2014/03/pause-for-placemaking/.
Pockets of Peace in the Urban Jungle. Tun Razak Exchange. (2019, March 4). https://www.trx.my/city/pockets-peace-urban-jungle.
Vulcan Real Estate. Vulcan Real Estate - Home. (n.d.). https://vulcanrealestate.com/.
KB.TH City College
Tourism & Hospitality City College
DESIGN REPORT School of Architecture, Building and Design
Master of Architecture
Urban Design Studio | ARC70109
Jason Yap Chi Wen 0342976